NAME DESCRIPTION POTENTIAL CAUSE TROUBLESHOOTING
E43 Ch3 overload up Overload up occurred on
channel 3
» Leg is overloaded
» Hit obstruction
» Reached end stop (before
initialization at upper end-
stop occurs)
•Remove obstruction (P3)
•Remove load
•Initialize if necessary (P1)
E44 Ch4 overload up Overload up occurred on
channel 4
» Leg is overloaded
» Hit obstruction
» Reached end stop (before
initialization at upper end-
stop occurs)
• Remove obstruction (P3)
• Remove load
• Initialize if necessary (P1)
E47 Ch1 overload down Overload down occurred on
channel 1
» Hit obstruction • Remove obstruction (P3)
• Initialize if necessary (P1)
E48 Ch2 overload down Overload down occurred on
channel 2
» Hit obstruction • Remove obstruction (P3)
• Initialize if necessary (P1)
E49
Ch3 overload down Overload down occurred
on channel 3
» Hit obstruction • Remove obstruction (P3)
• Initialize if necessary (P1)
E50
Ch4 overload down Overload down occurred
on channel 4
» Hit obstruction • Remove obstruction (P3)
• Initialize if necessary (P1)
E53
Ch1 anti-col Anti-collision triggered
on channel 1
» Hit Obstruction • Remove obstruction (P3)
• Initialize if necessary (P1)
E54
Ch2 anti-col Anti-collision triggered
on channel 2
» Hit Obstruction • Remove obstruction (P3)
• Initialize if necessary (P1)
E55
Ch3 anti-col Anti-collision triggered
on channel 3
» Hit Obstruction • Remove obstruction (P3)
• Initialize if necessary (P1)
E56
Ch4 anti-col Anti-collision triggered
on channel 4
» Hit Obstruction • Remove obstruction (P3)
• Initialize if necessary (P1)
E59
Ch1 SLS/PIEZO Safety limit switch activated
on channel 1
» Hit Obstruction • Remove obstruction (P3)
• Initialize if necessary (P1)
E60
Ch2 SLS/PIEZO Safety limit switch activated
on channel 2
» Hit Obstruction • Remove obstruction (P3)
• Initialize if necessary (P1)
E61
Ch3 SLS/PIEZO Safety limit switch activated
on channel 3
» Hit Obstruction • Remove obstruction (P3)
• Initialize if necessary (P1)
E62
Ch4 SLS/PIEZO Safety limit switch activated
on channel 4
» Hit Obstruction • Remove obstruction (P3)
• Initialize if necessary (P1)