IS339 ECN3539
4
TECHNICAL SPECIFICATION
Model EB3F EB4F EB6F EB6TF
Width mm
290 290 455 455
Depth mm
465 465 465 465
Height mm
655 655 655 655
Power Rating kW
3.0 4.5 6.0 6.0
Net weight net kg
13 13 17 17
Ambient temperature
o
C
5 to 30
Water inlet pressure Bar
1 to 8
ACCESSORIES
Wall mounting kit for EB3F, EB4F BR49
Wall mounting kit for EB6F, EB6TF BR50
Replacement filter cartridge FC02
INSTALLATION
The boiler must be installed on a horizontal surface in a location where it can
be supervised by trained personnel.
Inform all users that the surfaces may become hot.
For safety regulations the plug or means of disconnection must always be
accessible.
Connecting to the electricity and water and waste supplies
The boiler must be earthed.
Check that the voltage of your electricity supply corresponds to the voltage
shown on the serial plate.
EB3F
The boiler is supplied with a 13 amp plug. If replacing the plug, connect the
terminals as follows:
• Green and yellow wire
Earth E
• Blue wire
Neutral
N
• Brown wire
Live L
For safety regulations the plug or means of disconnection must always be
accessible.