IS339 ECN3539
8
7 Press the power button to cycle through the values 35 to 60. Press the
Fn button to select the required value
8 Press the power button to exit.
Standby
If the boiler is to be left unused for a long period, the element can be turned
off by pressing the power button.
Filter replacement
The FILTER display shows the estimated remaining life in the current filter
cartridge. When the filter needs replacing, a reminder message is displayed.
This is followed by the change filter screen.
The boiler can be used without a filter but scale may build up more quickly
and water taste may be affected.
Replace the filter as follows:
1 Twist the base of the filter 90 degrees to the left and carefully lower the
filter cartridge out of the unit. It will contain a small amount of water
2 Remove the black cap and place on the new filter
3 Insert the filter fully into its recess and twist to the right to lock in place
4 Press and hold the “Fn” button for 5 seconds to reset the filter life
monitor
5 Drain off approximately 5 litres of water to remove any loose carbon
particles from the filter