Form 404130
JULY 2010
MODEL 877
METERING CONTROL VALVE
Series “A”
SPECIFICATIONS:
Dial Capacity 32 Ounces - 16 Quarts
Totalizer Quarts
Flow Max. 4 Gallons per min. (15 liters per min.)
Flow Min. 0.4 Gallons per min. (1.5 Liters per min.)
Operating Pressure Max. 1000 PSI (70 Bar)
Operating Temp. Max. 110° F (45° C)
Accuracy +/- 0.65%
Weight 3.3 Lbs. (1.5 Kg.)
Meter Inlet Threads 1/2 NPT
(IOM-094-02 P/N 53400-094
Rev. 2)
New metering systems must be purged prior to installation
of metering control calce to free system of contaminates.
The automatic nozzle requires 60 PSI to open and function
properly. A pump exceeding 60 PSI is required for adequate
ow and proper operation. A pump ratio of at least 3:1 os
recommended.
OPERATION
The meter can handle petroleum products such as automatic
transmission fl uid, S.A.E. 5 to 50 weight motor oil, S.A.E. 80 to
240 weight gear oil and antifreeze fl uid (ethylene glycol).
The meter can be locked in the on position by engaging the trig-
ger lock, to release the lock the trigger must be depressed thus
releasing the lock. Before each use reset the meter by rotating
the indicator knob counterclockwise to zero.
HOSE
91241
84799 NOZZLE
(NON-DRIP)
90464
SWIVEL
68410
BASIC METER
TURN TO OPEN
NOZZLE
Systems which will be dispensing uids under pressure
may need to be protected by using a thermal relief kit which
will safely limit the pressures caused by thermal expan-
sion. Please contact your local Lincoln distributor and refer
to Section K5, Page 31 for more details. Failure to include
thermal relief protection may cause damage not covered
under Lincoln’s warranty policy.
WARNING
IMPORTANT NOTE:
©
©
Indicates change
Americas:
One Lincoln Way
St. Louis, MO 63120-1578
USA
Phone +1.314.679.4200
Fax +1.800.424.5359
Europe/Africa:
Heinrich-Hertz Str 2-B
D-69183 Waldorf
Germany
Phone +49.6227.33.0
Fax +49.6227.33.259
Asia/Pacifi c:
25 Int’l Business Park
#01-65 German Centre
Singapore 609916
Phone +65.562.7980
Fax +65.562.9967
© Copyright 2010
www.lincolnindustrial.com
Question and Answer IconNeed help?

Do you have a question about the Lincoln 877 and is the answer not in the manual?

Lincoln 877 Specifications

General IconGeneral
BrandLincoln
Model877
CategoryControl Unit
LanguageEnglish

Summary

Troubleshooting Meter Control Valve Issues

No Material Flow Troubleshooting

Diagnoses causes for complete lack of fluid dispensing from the meter.

Partial Material Flow Diagnosis

Addresses issues leading to reduced or insufficient fluid output.

Metering Indicator Discrepancies

Covers scenarios where the odometer or indicator fails to register or turn.

Leaks and Faulty Nozzle Issues

Details causes for leaks after shut-off, oil leaks, and faulty nozzles.

Pre-Set Operation Mode

Explains the condition of 'Pre-Set Only' without auto shut-off.

Safety and Operational Guidelines

Thermal Relief Protection

Importance of thermal relief kits for dispensing fluids under pressure.

System Purging Procedure

Requirement to purge new metering systems before installation.

Automatic Nozzle Pressure Requirements

Specifies the minimum pressure needed for proper nozzle operation.

Meter Operation and Specifications

Fluid Compatibility and Operation

Lists compatible petroleum products and basic operational steps.

Performance and Physical Specifications

Details dial capacity, flow rates, pressure, temperature, accuracy, and weight.

Service Parts and Component Identification

Meter Component Breakdown

Identifies and lists part numbers for meter components.

Pointer Operation Caution

Warns against turning the pointer clockwise to prevent damage.