ELECTRONIC LUBE METER
MODEL 967
Series “C’
FEATURES
• LargeSixDigitLCDDisplaywithtwodecimalpointprecision
• DispenseTotalDisplayinPints,Quarts,GallonsorLiters
• Unitofmeasureselectablefromthefrontofregister
• TotalizationinGallonsandLiters
• ResettableandNonresettableTotalizer
• DisplayOperationTemperatureRange-4°Fto140°F
• LowBatteryIndicator
• LonglifeFiledreplaceableToploadbattery
• Accuracyof(+-)0.5%
• Calibrationfactorprogrammablefromfrontofregister
• CalibrationFactorsavedinnon-volitilememory
• 1500PSIPressureRating©
• NPTandBSPThreadsavailable
SPECIFICATIONS
Flow(Maximum) 5GPM(19Liter/Minute)
Flow(Minimum) 0.25GPM(0.95Liter/Minute)
OperatingPressure(Maximum) 1500PSI(100Bar)
OperatingPressure(Minimum) 5PSI(0.35Bar)
OperatingTemp.(Maximum) 140°F(60°C)
OperatingTemp.(Minimum) -4°F(-20°C)
Accuracy +/-0.5%
Weight 3.7Lbs.(1.7KG)
5-DigitLCDDisplay,5/16”high Gallons,Pints,Quarts,Liters
InletandOutletConnections 1/2”NPTF
91241
HoseAssembly
84799
Non-DripNozzle
90464
Swivel
Newmeteringsystemsmustbepurgedpriortoinstallationofme-
teringcontrolvalvetofreesystemofcontaminates.
DESCRIPTION
Theelectroniclubemeterisdesignedspecicallytodispensemotor
oils(S.A.E.5-50),gearoils(S.A.E.80-240),automatictransmission
uid,andantifreeze(EthyleneGlycol)solution.
Theelectronicregistermodulecontainsamicroprocessorboardpow-
eredbyaLithiumbatterywithanexpectedlifeof3to5yearsdepend-
ingonuse.Itcanbeprogrammedtodispenseinpints,quarts,liters,
orgallonsandwilltotalizeinlitersorgallons.Acalibrationfactorand
unitofmeasureareprogrammedduringfactorytest.Unlikemechani-
calmeters,theseunitscanbeelectronicallyre-calibratedintheeld
whennecessary.A5-digitliquidcrystaldisplay,accuratetothesecond
decimalplace,showstheexactamountofuiddispensed.Theentire
registermoduleisprotectedfromthewearandtearofnormalshop
usebyarugged,glasslled,shockresistant,nylonhousing.
OPERATION
Asuidpassesthroughthemeteringchamberbyenteringtheinlet
port,itforcestheinternalgearstorotateandexitsthroughtheoutlet
port.Eachrotationofthegeardisplacesagivenvolumeofuid.
Thedisplayshowstheamountofuiddispensedsincethelasttime
theresetbuttonwaspushed.pushingtheresetbuttowillresetthe
displaytozeroforthenextdispense.
IMPORTANT NOTE:
Theautomaticnozzlerequires60PSItoopenandfunctionprop-
erly.Apumpexceeding60PSIisrequiredforadequateowand
properoperation.Apumpratioofatleast3:1isrecommended.
ToChangetheUnitofMeasure:
1. PresstheTOTALbuttonthreetimes,followedbytheRESET
buttonthreetimeswithinatimeframeoftwoseconds.Theactive
unitmeasuresymbolbeginsashing,indicatingthatyouaren
programmingmode.
2. PresstheRESETbuttonrepeatedlyuntilthedesiredunitofmea-
sureappearsashinginthedisplay.
3. SimultaneouslypressandholdtheRESETbuttonandtheTOTAL
buttonforaboutthreesecondstoenterthenewunitofmeasure
andtoexitprogrammingmode.
©Indicateschange
Systemswhichwillbedispensinguidsunderpressuremay
needtobeprotectedbyusingathermalreliefkit,whichwill
safelylimitthepressurescausedbythermalexpansion.
PleasecontactyourlocalLincolndistributorandreferto
ServicePageSectionK5,Page31formoredetails.Failure
toincludethermalreliefprotectionmaycausedamagenot
coveredunderLincoln’swarrantypolicy.
©
©