FLOWMASTER HYDRAULIC PUMP
Repair Instruction
Repair Kits
275382 Upper Plunger and Pivot Kit
Includes new style upper plunger and bushing with all seals
(Items 9, 10a, 10b, 10c,10d) new style wrist pin anchor (Item
13A), new style wrist pin bushings and screws (Items 12a and
11A) and new style cup and backup washer (Items 15a & 14a).
This kit ts into old style pumps to repair and upgrade older
units.
275381 Housing Cover Kit
Includes cover screws with gaskets, dipstick with O-ring, hous-
ing cover and housing cover gasket (Items 28, 29, 30a, 30b,
30 and 31).
This kit ts olde style pumps wot repair and upgrade older
units.
275188 Pivot Pin and Anchor Kit
Includes Pivot Screw (Item 11), Wrist Pin Bushing (Item 12)
and Spacer. This kit ts old style pumps for repair and up-
grade of older units.
275186 Upper Bushing and Plunger Kit
Includes upper plunger with pitted bushing.
For use on new style FlowMaster pumps (use kit 275382 to
repair and upgrade older style pumps.
275187 Lower Bushing and Plunger Kit
Includes lower plunger with tted bushing (Item 19a), O-ring
seal (Item 26a) and lower cup seals (Item 21).
This kit ts into old style pumps to repair and upgrade older
units.
275193 (5 gal), 275194 (60 lb), 275195 (120 lb) and 275196
(400 lb) Housing Tube Kits.
Includes housing tube (Item 56a), bushing preinstalled in hous-
ing tube (Item 57) and inlet screen (Item 56b).
These kits t older style pumps for repair and updating older
units.
Repair Kit Selection Chart
Damaged Part to be
Replaced Old Style Pumps New Style Pumps
Items 1 - 9 Parts are identical
Items 10 - 10d
Use Kit 275382 to upgrade
pump
Use Kit 275186 to repair
pump.
Items 11 - 13 Note:
Items 14 & 15 must be
used with new style
wrist pin anchor, Item
13a.
Use kit 275188 with spacer
275376 to upgrade pump.
O-ring (Item 13b) is not
needed when used with old
style upper cup seal.
Use kit 275188 without
spacer 275376 to repair
pump. Use O-ring (Item
13b) with new style upper
cup seal (Item 15)
Items 16 - 20
Parts are interchangeable or identical. Using 20 on old
style pumps improved the life of the crankcase oil seal.
Items 19 - 21
Use Kit 275187 to upgrade
pump.
Use Kit 275187 to repair
pump.
Items 24 - 27 Parts are interchangeable or identical.
Items 28 - 31
Use Kit 275381 to upgrade
pump. New cover has a
dipstick feature.
Use Kit 275381 to repair
pump.
Items 39 - 41 Parts are identical
Items 42 - 51a Parts are identical
Items 52 - 55 Parts are identical
Items 56a - 57
Use Kits:
275193 (5 gal)
275194 (60 lb)
275194 (120 lb)
275196 (400 lbs)
to upgrade pumps.
Use Kits:
275193 (5 gal)
275194 (60 lb)
275194 (120 lb)
275196 (400 lbs)
to repair pumps.
Items 58 - 67 Parts are identical