EasyManua.ls Logo

Linear ACCESS AK-21 - User Manual

Linear ACCESS AK-21
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
AK-21
Digital Keyless
Entry System
(760) 438-7000
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
www.linearcorp.com
228045 A IMAGE 1
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,AK-21 - LINEAR P/N: 228045 A - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - FOLDING: ALBUM-FOLD - BINDING: SADDLE-STITCH
Installation and Programming Instructions
Question and Answer IconNeed help?

Do you have a question about the Linear ACCESS AK-21 and is the answer not in the manual?

Linear ACCESS AK-21 Specifications

Power IconPower
voltage12-24 Volts AC or DC
current typical30 mA
current maximum150 mA
Outputs IconOutputs
main relay current5 Amps @ 28 Volts maximum
auxiliary relay current1 Amp @ 28 Volts maximum
solid state outputs current100 mA @ 24 VDC maximum
Operating Environment IconOperating Environment
temperature range-22°F to 149°F (-30°C to 65°C)
humidity range5% to 95% non-condensing
Weight and Dimensions IconWeight and Dimensions
width3.00 inches
height5.00 inches
depth3.00 inches

Summary

Keypad Features

Form C Relay Contacts

Main Relay (5A) and Auxiliary Relay (1A) for switching.

Input Functions

Door Sense, Inhibit, and Request-to-Exit inputs supported.

Wiring Diagram

Terminal Block Connections

Details for AK-21 terminals TB1 and TB2.

Wiring Notes and Cautions

Important instructions and safety warnings for wiring.

Installation

Opening the Keypad

Steps to disassemble the keypad for installation.

Keypad Wiring

Door Strike Wiring

Connecting the electric door strike to the keypad.

Power Supply Wiring

Connecting the power source to the keypad terminals.

Sense Input Wiring

Wiring for door sense or inhibit functions.

Request-to-Exit Input Wiring

Connecting a pushbutton for codeless access.

Factory Defaults

Basic Programming

Entering Programming Mode

Procedure to enter programming mode with master code.

Programming Tasks

Adding Entry Codes

Steps to add new entry codes and assign relay actions.

Erasing Entry Codes

Procedures for deleting single or all entry codes.

Changing Master Code

Procedure to update the 6-digit master programming code.

Programming Options

Door Sense or Inhibit Input

Configure input terminal #8 for door sense or inhibit.

Keypad Lockout and Anti-Passback

Resetting the Keypad

Master Reset Procedure

Clears all settings and entry codes to factory defaults.

Resetting the Master Code

Procedure to reset the master code to the default (123456).