1. Specications
1.1. Technical
Minimum Breaking Strength (MBS): 90 kN
Working Load Limit (WLL): 30 kN
PPE Load Limit: 25 kN
Operating temperature range: -10° to +40° C
Relative operating humidity: 10% to 80% RH
Weight: 520 g
Measure L x H x W: 190 x 90 x 20 mm
Size load eyes: 60 x 40 mm (R30 D-Shape)
Material body: Aviation aluminum alloy LY12CZ
Protection Class: IP66
1.2. Designation of use
The LineScale is an electronic Bluetooth load cell designed for industrial and rescue PPE application.
For PPE application use is limited to suspension of one person only!
It is highly recommend to not exceed 10kN load in PPE application.
In PPE relevant applications this equipment is to be used by trained PPE personnell only.
Ensure a rescue plan is in place to deal with any emergencies that could arise during PPE use.
Warning: May only be used when no medical pre-conditions apply that could impede safe PPE use.
2. Nomenclature of parts & Marking
Load eye
Load eye
Device
Serial-No.
Display
Body
XX:XX:XX
USB-Ports
Master
Slave
LineGrip LineScale-3
Electronic Bluetooth Load-Cell
www.linegrip.com/ls3
WLL 30 kN (3t)
MBS 90 kN (9t)
Designed in Germany
by LineGrip Corp. Ltd.
67714 Waldfis chba ch
+49-170-9969192
www.linegrip.com
Manufactured in China
DOM08/21
• Batch 001
PPE-R/11.114 V3:2021 • 1019
This device is certifie d to be used as
Personal Protective Equipment
(PPE) Recommendation: do not exceed 10 kN (1000kg) !
UIAA 130 V1:2021 (25kN)
(load sharing devices)
RF regulations
BQB BLE 4.2/5.0
CE ETSI RED, IC
FCC ID: 2ADXE-
HY-40R204PC
WLL designation
MBS designation
Notied body
no. 1019 (CE)
Recommended
PPE load
QR-Code to
product website
Date of
manufacturing
& Batch-No.
Certication
regulations
3. Compatibility
3.1. Connectors
Depending on the eld of application, for the connection only use EN 362 connectors specic for
work at height or EN 12275 connectors specic for mountaineering activities, equipped with
locking gates, or attach ropes & slings directly to the load eyes.
3.2. Anchor Points
Only use anchor points complying with EN 795 standards (minimum strength 12 kN or 18 kN for
non-metallic anchors), located above the user’s position.
RF regulations
Note: CE = Conformité Européenne (European Conformity)
Read manual
before use!
RF regulations
BQB BLE 4.2/5.0
CE ETSI RED, IC
FCC ID: 2ADXE-
HY-40R204PC
Device name