LK-CP64X Control Panel (6A)
¢ Terminal
03 04
Symbol
Descripon
Symbol
Descripon
L
AC live wire
FSO
Fire signal output
N
AC null wire
FOO
Fire output NO
E
AC earth wire
FOC
Fire output NC
V+
24VDC input posive
24V
24VDC+ output
V-
24VDC input negave
FSI
Fire signal input
M+
24VDC motor posive
COM
Sensor COM
M -
24VDC motor negave
S+
Slave control up
MU
Manual switch up
S-
Slave control down
MS
Manual switch stop
12V
DC12V+ output
MD
Manual switch down
WRD
Rain sensor down
MG
Manual switch GND
T/H
T/H signal
Power Supply
V+
L
V-
N
E
MG MD MS MU M1+ M1- M2+ M2- M3+ M3-M4+ M4- V- V+
FSO
FOO
FOC
24V
FSI
COM
S+
S-
12V
WRD
T/H
Control Board
ON
Y
N
S-TH
¢ Manual control
Aer power on all the LEDs light for 1 second and turn off, the power indicator LED
normally on
Press reset buon, all the LEDs light for 1 second and turn off, reset successfully
L2 will be explosion-flashing aer controller receives fire signal
External manual switch is equivalent to controller panel switch
The maximum running me of the motor is 5 minutes
.
.
£ Group control
By default, L1 is normally on, the rest LEDs are off as group control status
Press UP buon, the windows open, LED turns on, turns off aer 5 seconds
Press DOWN buon, the windows close, LED turns on, turns off aer 5 seconds
Press STOP buon, ,the motors stop, LED turns on, LED turns off aer 1 second
£ Channel control
Press channel selecon keys the corresponding LED lights, channel selected
Press the channel selecon buon again or no operaon on controller thin 10 seconds,
LED turns off, channel unselected
In the process of opening/closing the current window, you can select another channel(s)
to drive the window
.
Can be used as a master controller, a slave controller or play a dual role of master & slave
controller at the same me
As a master controller, connects to the motors or slave controllers to drive them
As a slave controller, input terminals S+ and S- are connected to the output terminals M+
and M- of the master controller to receive the instrucons to drive motors, or drive the
motors independently
Play a dual role of master & slave controller, not only controlled by higher-level controller,
but also drive motors or lower-level controllers independently
No maer master, slave or both, it can process all the external signals such as manual
switch, remote and sensors
Cascade use of the controller, if the master controller connected to an external sensor
(such as smoke sensor, wind and rain sensor, etc.), the slave controller MUST NOT use
inching mode, in case the master controller received the smoke signal to open the
window, the slave controller will open the window for a very short moment and stop
¢ Cascaded control