www.linkayl.com
Copyright © Linkayl Technology Limited
LK-CP64X Control Panel (6A)
¢ Terminal
03 04
Power Supply
V+
L
V-
N
E
MG MD MS MU M1+ M1- M2+ M2- M3+ M3-M4+ M4- V- V+
FSO
FOO
FOC
24V
FSI
COM
S+
S-
12V
WRD
T/H
Control Board
ON
Y
N
S-TH
¢ Manual control
— Aer power on all the LEDs light for 1 second and turn off, the power indicator LED
normally on
— Press reset buon, all the LEDs light for 1 second and turn off, reset successfully
— L2 will be explosion-flashing aer controller receives fire signal
— External manual switch is equivalent to controller panel switch
— The maximum running me of the motor is 5 minutes
.
.
£ Group control
— By default, L1 is normally on, the rest LEDs are off as group control status
— Press UP buon, the windows open, LED turns on, turns off aer 5 seconds
— Press DOWN buon, the windows close, LED turns on, turns off aer 5 seconds
— Press STOP buon, ,the motors stop, LED turns on, LED turns off aer 1 second
£ Channel control
— Press channel selecon keys the corresponding LED lights, channel selected
— Press the channel selecon buon again or no operaon on controller thin 10 seconds,
LED turns off, channel unselected
— In the process of opening/closing the current window, you can select another channel(s)
to drive the window
.
— Can be used as a master controller, a slave controller or play a dual role of master & slave
controller at the same me
— As a master controller, connects to the motors or slave controllers to drive them
— As a slave controller, input terminals S+ and S- are connected to the output terminals M+
and M- of the master controller to receive the instrucons to drive motors, or drive the
motors independently
— Play a dual role of master & slave controller, not only controlled by higher-level controller,
but also drive motors or lower-level controllers independently
— No maer master, slave or both, it can process all the external signals such as manual
switch, remote and sensors
— Cascade use of the controller, if the master controller connected to an external sensor
(such as smoke sensor, wind and rain sensor, etc.), the slave controller MUST NOT use
inching mode, in case the master controller received the smoke signal to open the
window, the slave controller will open the window for a very short moment and stop
¢ Cascaded control