Rev: 07.25.18 Page 7
CCD-0001504
NOTE: The following process will be repeated for both sensor installations.
NOTE: Leveling sensor mounting plate may already be pre-installed by LCI.
1. Dry fit the mounting plate (Fig. 8C) and the leveling sensor (Fig. 8B) to the crossmember (Fig. 8A). The
pre-drilled holes in the plate are for mounting the sensor to the plate. Mark on the plate where the
sensor will set.
NOTE: Space between the sensor and crossmember MUST be left so the wire harness will not be pinched.
NOTE: The wire harness MUST be oriented towards the front of the trailer. Orientation is imperative for the
correct operation of the leveling system.
2. Attach the sensor (Fig. 9A) to the mounting plate (Fig. 9B) using two #12 - 14 x 1" hex head self-
tapping screws (Fig. 9C).
3. Attach the mounting plate and sensor assembly (Fig. 10B) to the crossmember (Fig. 10A) using two
#12 - 14 x 1" hex head self-tapping screws (Fig. 10C). Ensure that the plate is centered side to side on
the frame and that the sensor is oriented properly. See Fig. 3 Sections A and B for location clarification.
4. Connect the sensor harness to the connector on the sensor (Fig. 11A) and run the harness through the
frame and up to the compartment where the controller will be mounted.
Fig. 8
A
B
C
Fig. 9
A
B
C
Fig. 10
x
x
A
B
C
Fig. 11