115
44 : During Fast Stop
The assigned output terminal closes during a fast stop. Refer to setting 21 and 22 (Fast Stop)
of multi-function Digital Inputs.
45 to 47 : Retain
48During Wobble operation
The assigned output terminal closes during wobble function operation.
49Retain
E3 Multi-Function Analog Input
The drive has two multi-function analog inputs (A1). Set the terminal A1 according to Table
6.21.
E3- 00 Terminal A1 Signal Level Selection
Sets the signal level for terminal A1.
No.
Name
Setting Range
Default
E3-00
Terminal A1 Signal Level Selection
0, 3
2
0 : 0 to 20 mA
1 : 4 to 20 mA
2 : 0 to 10 V
Inputs a 0 to 10 V signal. A negative signal by the gain and voltage bias is limited to 0%.
3 : 0 to 5 V
Inputs a 0 to 5 V signal. A negative signal by the gain and voltage bias is limited to 0%.
E3- 01 Terminal A1 Function Selection
Select the function to terminal A1.
No.
Name
Setting Range
Default
E3-01
Terminal A1 Function Selection
0 to 19
0