Output
frequency
Bias
Up 2
command
Bias value is increasing when the
acc./dec. times set to L4-02
Less
than 2s
Less
than 2s
More
than 2s
Figure 6.39 Up 2/Down 2 Bias when L4-010.0 Hz
L4-02 Frequency Command Acc./Dec Setting ( Up / Down 2)
Sets the acceleration/deceleration times to increase or decrease the frequency command bias
for Up/Down 2.
No.
Name
Setting
Range
Default
L4-02
Frequency Command Acc./Dec Setting ( Up2 / Down 2)
0, 1
0
0 : Current Acc./Dec. Time
The drive uses the currently active acceleration or deceleration time.
1 : Not choosen Acc./Dec. Time
L4-03 Up/Down Frequency Command Save
No.
Name
Setting Range
Default
L4-03
Up/Down Frequency Command Save
0.00 to 400.0
0.00 Hz