1
Thank you for buying this energy efficient water heater. We
appreciate your condence in our products.
You should thoroughly read this manual before installation and/or
operation of this water heater. Please pay particular attention
to the important safety and operating instructions as well as the
WARNINGS and CAUTIONS.
Instruction Manual
PRINTED 1011 322923-000
KEEP THIS MANUAL IN THE POCKET ON HEATER FOR FUTURE REFERENCE
WHENEVER MAINTENANCE ADJUSTMENT OR SERVICE IS REQUIRED.
ALL TECHNICAL AND WARRANTY QUESTIONS: SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS
PURCHASED. IF YOU ARE UNSUCCESSFUL, PLEASE WRITE TO THE COMPANY LISTED ON THE RATING PLATE ON THE WATER HEATER.
RESIDENTIAL GAS WATER HEATERS
For Your Safety
AN ODORANT IS ADDED TO THE GAS USED
BY THIS WATER HEATER.
GAS MODELS POWER VENT LVL07580(S), LVN07580(S)
WITH HOT SURFACE IGNITION
Low Lead Content
300 Maddox Simpson Parkway
Lebanon, TN 37090
Phone: 615-889-8900 • Fax: 615-547-1000
Technical Service email: 2tech@lochinvar.com
www.Lochinvar.com

Table of Contents

Questions and Answers

  • M
    Molly HardyAug 18, 2025
    What to do if the temperature adjust buttons are stuck on my Lochinvar LVL07580?
    • J
      Jessica JonesAug 18, 2025
      If the self-diagnostic check on your Lochinvar Water Heater detects that one or both of the temperature adjust buttons are stuck, press and release both temperature adjust buttons several times, then cycle the water heater power off and on. If the error code persists, replace the gas control valve/thermostat.
  • J
    John BradleyAug 20, 2025
    What to do if my Lochinvar LVL07580 has ignition failure?
    • R
      Rita ShermanAug 20, 2025
      If your Lochinvar Water Heater is experiencing ignition or flame failure and is locked out after three retries, you can reset it by cycling the power off and on. Also, ensure the flame sensor is making good contact with the burner flame and the flame is steady. Check that the gas supply is turned on and pressure is adequate, and that supply and manifold gas pressures are within the requirements in the installation manual. Clean the flame sensor with fine steel wool. Also, check the igniter assembly plug and socket for a good connection. If the plug is worn or damaged, replace the igniter assembly. If the socket is worn or damaged, replace the gas control valve/thermostat. As a last resort, replace the igniter assembly.
  • K
    Kyle RoblesAug 23, 2025
    How to fix earth ground issues in my Lochinvar LVL07580?
    • C
      Carol BlackAug 23, 2025
      If the gas control valve/thermostat in your Lochinvar Water Heater senses inadequate or no earth ground, make sure the wall outlet (power supply) is properly grounded. Also, ensure all ground connections/wires on the water heater are securely connected.
  • J
    Jessica MckeeAug 26, 2025
    What to do if my Lochinvar LVL07580 Water Heater has gas valve driver circuit issues?
    • K
      Kristopher LoveAug 26, 2025
      If the self-diagnostic check on your Lochinvar Water Heater detects a problem with the gas valve driver circuit, internal microprocessor, or other internal circuits, turn the power off for 10-20 seconds, then turn it back on to clear the error codes. If the error codes persist or cannot be cleared, replace the gas control valve/thermostat.
  • S
    Sally Newton MDAug 28, 2025
    How to troubleshoot an open igniter circuit in my Lochinvar LVL07580?
    • M
      michelle51Aug 28, 2025
      If the gas control valve/thermostat of your Lochinvar Water Heater detects an open igniter circuit, check the wiring to the hot surface igniter assembly, and replace the igniter assembly if the wiring is damaged or worn. Check the resistance of the igniter at the igniter assembly plug; it should be between 11 and 18 ohms at room temperature (77° F at plug end). Replace the igniter if it's open or shorted. Also, check the igniter assembly plug and the socket on the gas control valve/thermostat for a good connection. Replace the igniter assembly if the plug is worn or damaged, and replace the gas control valve/thermostat if the igniter assembly socket on the bottom of the control is worn or damaged.
  • C
    charleswhiteAug 30, 2025
    What to do if my Lochinvar Water Heater's ECO is activated?
    • R
      Ryan RogersAug 30, 2025
      If the water temperature in your Lochinvar Water Heater tank exceeds 195° F and activates the ECO, turn the power off for 10-20 seconds, then turn it back on to clear the error codes. If the error code persists, replace the gas control valve/thermostat.
  • C
    Catherine WatersSep 2, 2025
    What causes the pressure switch circuit to remain open in my Lochinvar Water Heater?
    • T
      Tammy HernandezSep 2, 2025
      If the pressure switch circuit remains open longer than 5 seconds after the blower is energized in your Lochinvar Water Heater, ensure the air pressure switch sensing tube is properly connected at both ends and is not kinked or damaged. Also, ensure the correct size of vent and intake air pipe (direct vent products) was used per the installation instructions in the manual that came with the water heater. Make sure the maximum number of elbows or maximum equivalent feet of vent or intake air pipe has not been exceeded per the installation instructions in the manual that came with the water heater. Finally, ensure there are no obstructions in the vent or intake air pipe.
  • J
    Joyce MillerSep 4, 2025
    What to do if the water temperature sensor is open or shorted in my Lochinvar Water Heater?
    • D
      Dr. Curtis SmithSep 4, 2025
      If the self-diagnostic check detects that the water temperature sensor in your Lochinvar Water Heater is either open or shorted, turn the power off for 10-20 seconds, then turn it back on to clear the error codes. If the error code persists, replace the gas control valve/thermostat.
  • C
    Christopher TorresSep 7, 2025
    What to do if the pressure switch circuit remains closed in my Lochinvar LVL07580?
    • T
      thomaskirkSep 7, 2025
      If the pressure switch circuit remains closed for more than 5 seconds after the heating cycle begins in your Lochinvar Water Heater, ensure the air pressure switch circuit wiring is correct and the air pressure switch is not jumpered. If problems persist, replace the air pressure switch.
  • C
    Connie HoltSep 9, 2025
    What to do if my Lochinvar LVL07580 has a problem with the black resistor wire on the ignitor assembly plug?
    • T
      Theodore RobertsonSep 9, 2025
      If the self-diagnostic check detects a problem with the black resistor wire on the ignitor assembly plug of your Lochinvar Water Heater, turn off the power to the water heater. Ensure the black resistor wire is not cut, missing, and is installed between pins 3 & 4 of the ignitor assembly plug. If damaged or defective, replace the ignitor assembly. If the error code persists, replace the gas control valve/thermostat.

Lochinvar LVL07580 Specifications

General IconGeneral
ManufacturerLochinvar
Model NumberLVL07580
Capacity75 Gallons
CategoryWater Heater
Water Connections3/4" NPT
Warranty6 years
Weight220 lbs