Review installation instructions carefully, comply with local codes, and use safety equipment due to sharp edges.
Space vents evenly on the roof slope, centering them on the roof length for optimal coverage.
Center the vent base seam on a rafter and mark positions 7-11/16 inches from its centerline.
Locate vents near the ridgeline, approximately 24" (36" Max.) down from it.
Scribe 9-1/2" diameter circles using marked positions and drill starter holes with a 1/2" bit.
Cut 9-1/2" circular openings using a keyhole or saber saw, carefully avoiding excessive size.
Remove top row nails and trim shingles to allow vent flashing to slide underneath for proper alignment.
Apply roofing cement to the bottom of the vent around the hole before installation.
Slide vent into place, ensuring the throat is centered over the hole, and fasten with roofing nails.
Seal all seams and nail heads with roofing cement, and use cement to secure loose shingle edges.
Install all exhaust vents at the same height within a common attic area for proper airflow.
Install only one type of exhaust ventilation within a common attic area to prevent airflow interference.
Install a balanced system with 50% intake and 50% exhaust ventilation for optimal attic climate control.