9. Troubleshooting
1) Engine Does Not Start
Possible Cause Correction
No diesel fuel Refuel fuel system
Improper diesel fuel Refuel whit recommended diesel fuel
Clogged fuel filter Replace fuel filter
Faulty spraying of fuel injection Purge of or replace fuel injection
Starter motor does not operate or rotates too
slowly (engine can be turned manually
Check electrolyte ,recharge
Clean terminals ,retighten
2) Engine Lacks Power
Possible Cause Correction
Fuel system clogged Purge of or replace fuel vitta ,filter or cock
Faulty spraying of fuel injection Purge of or replace
Faulty of fuel injection pump Purge of or replace
Clogged air cleaner element Clean or replace filter element.
3Black exhaust smoke
Possible Cause Correction
Engine overloaded Reduce load
Improper diesel fuel Replace with recommended diesel fuel
Faulty spraying of fuel injection Purge of or replace
Clogged air cleaner element Clean or replace filter element.
10. Overall Dimensions And Installation:
LC178F(D)