Do you have a question about the LONGI LR5-54HPH M Series and is the answer not in the manual?
| Maximum Power Output | 415W |
|---|---|
| Weight | 21.5 kg |
| Cell Type | Monocrystalline |
| Operating Temperature | -40°C to +85°C |
| Rated Power | 415W |
| Maximum Power Voltage (Vmp) | 41.6V |
| Maximum System Voltage | 1500V |
| Dimensions | 1722mm x 1134mm x 30mm |
| Number of Cells | 108 |
| Model | LR5-54HPH |
| Warranty | 25 years |
Details on module identification labels, including nameplate, classification, and serial number.
Description of junction box styles and recommended wiring methods for PV modules.
General safety precautions for installation and handling of PV modules.
Safety guidelines concerning electrical hazards and module performance during installation and operation.
Safety considerations for the operation and handling of PV modules.
Fire protection requirements and ratings applicable to PV modules.
Guidelines for selecting appropriate installation sites and suitable working environmental conditions.
Guidance on selecting optimal tilt angles for PV modules to maximize power output.
General requirements for mechanical installation, including load bearing and material specifications.
Details on the mechanical installation of monofacial modules using various mounting methods.
Instructions and specifications for the mechanical mounting of modules using bolts.
Instructions and specifications for the mechanical mounting of modules using clamps.
Installation methods and mechanical load capacities for monofacial modules.
Guidelines for the mechanical installation of bifacial modules.
Instructions for mounting bifacial modules using bolts.
Instructions for mounting bifacial modules using clamps.
Installation methods and mechanical load capacities for bifacial modules.
Electrical characteristics, series/parallel connection, and voltage calculations for PV modules.
Guidelines for the selection and installation of cables and wiring for PV modules.
Best practices and precautions for connecting PV module connectors.
Functionality and handling of bypass diodes within PV module junction boxes.
Information on Potential Induced Degradation (PID) and inverter compatibility for PV systems.
Method for grounding PV modules using a grounding clamp.
Method for grounding PV modules using unoccupied mounting holes.
Usage guidelines for third-party grounding devices with LONGi modules.
Procedures and recommendations for cleaning PV modules to maintain performance.
Visual inspection guidelines for identifying cosmetic defects on PV modules.
Periodic inspection of PV module connectors and cables.