S15 Pre-Installation and Site Preparation Guide
1008236 Rev B
Loring Smart Roast Proprietary This document is controlled by
Document Control. By printing this document, it will become a “Reference” copy.
Users are responsible for verifying that it is the latest revision available.
Page 9 of 46
S15 Specications
S15 Specication Value
System Weight
1
1573 lb (714 kg) uncrated
Maximum Batch Size 33 lb (15 kg)
Minimum Batch Size 6.6 lb (3 kg)
Nominal Electrical Power 2.8 kW
Peak Electrical Power 5.8 kW
Maximum BTU Rating 130,000 BTU/hr (33 K kcal/h)
Hot Stack Max Continuous Temperature
2
1400 °F (760 °C)
Hot Stack Max Intermittent Temperature
2
1500 °F (816 °C)
Hot Stack Max Flow
3
22 dscfm (37 dsm3/h)
Hot Stack Max Flow (Peak Air Cool)
5
310 dscfm (527 dsm3/h)
Hot Stack Minimum Duct Diameter
4
6 in (152 mm)
Cooling Exhaust Max Flow
5
980 scfm (1670 sm3/h)
Cooling Duct Diameter
4
6 in (152 mm)
Table 1. S15 Basic Equipment Specications
Notes:
1 Exact system weight may depend on options selected.
2 Consult local and regional regulations for air quality, temperature, and emissions restrictions.
3 Dry, or water content of the ue removed, under standard pressure and temperature conditions,
i.e. 29.9 in HG (760 mm HG) and 68°F (20°C).
4 Larger stack diameters or stack openings may be required under some conditions.
5 Add the Hot Stack Max Flow (Peak Air Cool) and Cooling Exhaust Max Flow to obtain the total
air ow out of the building. This may be needed in the event that additional air intake, otherwise
known as makeup air, is needed at the installation site.