MAINTENANCE
Translation of the original instructions
24
6 MAINTENANCE
6.1 Routine
When using the appliance over time, it is essential to perform regular maintenance to ensure safe operation.
We therefore recommend stipulating a service contract.
Caution
Maintenance must only be performed by specialist personnel in compliance with current
regulations and our own instructions.
Before carrying out any maintenance and/or cleaning operation:
· Disconnect the appliance from the mains power supply and/or close the gas.
· Wait for a sufficient time for the appliance to cool down.
· Do not wash the appliance with direct or high-pressure jets of water, since any infiltration of water into the
electrical components could jeopardise correct operation of the appliance and its safety systems.
Warning
For maintenance/replacement of components, order and use only original spare parts.
Replacing parts must exclusively be performed by authorised and/or qualified personnel. When replacing the
electrical components of the machine and the electrical panels, scrupulously follow the technical
characteristics for the replacement component indicated on the component itself. The appliance does not
require any special maintenance but during the use of the equipment it is advisable to check the following at
least once a year (possibly increasing the frequency depending on the degree of use):
· The status of connections especially on the terminal board and the power supply cable, as well as the
status of the gas connections;
· The operating condition of the various components (perform a functional test);
· For appliances fitted with rotary resistances, remove the hub, grease it and replace the three o-ring seals
to avoid possible leaks.
6.2 Replacing the main burner nozzle
· Remove the front screws fastening the dashboard/panel and pull it outwards
· Detach the starter cable
· Using a suitable wrench, unscrew the nozzle and replace it with an appropriate new one
· The main burner does not require any regulation of the primary air
6.3 Replacing the pilot burner nozzle
The pilot burner flame has a fixed air supply. The only necessary item is replacement of the nozzle
depending on the type of gas used (see technical data table).
· Unscrew the coupling connecting the pilot tube to the pilot itself and slide out the nozzle to be replaced
· Replace the nozzle with the appropriate version and make sure that, after ignition, the flame correctly
touches the tip of the thermocouple

Other manuals for Lotus CP-94G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lotus CP-94G and is the answer not in the manual?

Lotus CP-94G Specifications

General IconGeneral
BrandLotus
ModelCP-94G
CategoryCommercial Food Equipment
LanguageEnglish

Related product manuals