Doc: I456GB06_16.docx 29/06/2016
p. 1 / 20
ADXL…
SOFT STARTER
INSTRUCTION MANUAL
Read the manual carefully before installation and use.
T
hese devices must be installed by qualified personnel, in compliance with current plant-engineering regulations, in order to avoid damage to persons or property.
Before any maintenance operation on the device, switch off power supply from measuring and supply inputs.
The manufacturer assumes no responsibility for electrical safety in the event of improper use of the device.
The products described in this document are subject to updates or modifications at any time. Data and descriptions in the catalogue therefore do not have any contractual value.
The building’s electrical system must incorporate a switch or circuit breaker. It must be installed close to the equipment and within easy reach of the operator. It must be marked as the disconnecting
device of the equipment: IEC/ EN 61010-1 § 6.12.2.1.
Clean the instrument with a soft cloth. Do not use abrasives, liquid detergents or solvents.
Contents Page
Description 2
Front button functions 2
Front LEDs 2
Display indications 2
UTOSET guided configuration
3
Navigating the display pages
4
Operational status 4
Remote keypad 4
Startup methods 5
Protections 5
Motor thermal protection 6
Motor thermal protection via PTC
6
Starter thermal protection 6
Main menu 7
Password-protected access
7
Inputs, outputs, internal variables
7
Limit thresholds (LIMx) 7
Remote variables (REMx) 7
User alarms (UAx) 8
IR programming port 9
Parameter setting from PC 9
Parameter setting from smartphone or tablet with CX02 Wi-Fi
dongle
9
Parameter setting from smartphone or tablet with NFC
9
Parameter settings (setup) from front panel
10
Parameter table 10
larms 13
larm properties 13
Table of alarms 14
Description of the alarms 14
Programmable input functions table
14
Programmable input defaults
settings
15
Programmable output functions table
15
Programmable output defaults
settings
15
Commands menu 16
Installation 16
Recommendations 16
Power factor correction 16
Connection diagrams 17
Mechanical dimensions 18
Terminal layout 18
Choosing the soft starter 19
Type 2 coordination 19
Technical characteristics 19
Manual review history 20
I456GB06_16