How to renew the closed breather system
1. Release the hose clips and remove the breather valve (A1).
Remark
If it is necessary, remove the breather body (A4) in rocker cover, so as to insert gauze strainer.
2. Remove the plastic gauze strainer (A2) and clean it with clean kerosene.
3. Clean the breather body with clean kerosene.
4. Renew the "O" ring (A3) if necessary.
5. Check that the inside of the breath pipe is clean. If the pipe is not clean, release the flange setscrews and remove
the pipe. Wash the pipe with kerosene and dry it with low pressure air.
6. Install the breather cover back to the breather body and ensure it has been secured installed.
7. Fit the breather pipe and tighten the hose clips.
Remark:
Breather body is secured into the rocker cover by thread. If it is necessary to renew the breather assemble,
use a “C” wrench to hold the flange of the bottom to loose the thread.