Appendix 1. Troubleshooting
App.1-10
Object
Error code
Occurrence
location
Error message Reason and measure
Type Address
Project
download
0x26
0x09
XP Builder
Failed to read USB
information.
Project is set to store data at USB storage
device equipped at device. By the way, now it
can’t read information about USB storage
device. Check the installation status of USB
storage device and if it is normal, check USB
storage device. If this problem is repeated,
contact Customer Service Center.
0x0A
XP Builder
Failed to read Flash
memory information.
In case that it can’t know information about
memory status, download is stopped. If this
problem is repeated, contact Customer
Service Center.
0x0B
XP Builder
Failed to clear Temp
Directory.
In case that because of error of Flash Disk, it
can’t delete the directory made temporally for
download because of error of Flash Disk,
download is stopped. If this problem is
repeated, contact Customer Service Center.
0x0C
XGT Panel
Failed to delete Font File.
Please reboot XGT
Panel.
In case that it fail to delete the font file of
previous project because of error of XGT
Panel, download is stopped. If this problem is
repeated, contact Customer Service Center.
0x0D
XGT Panel
Failed to delete Image
File. Please reboot XGT
Panel.
In case that it fail to delete the image file of
previous project because of error of XGT
Panel, download is stopped. If this problem is
repeated, contact Customer Service Center.
0x0E
XGT Panel
Failed to delete Sound
File. Please reboot XGT
Panel.
In case that it fail to delete the sound file of
previous project because of error of XGT
Panel, download is stopped. If this problem is
repeated, contact Customer Service Center.
0x0F
XGT Panel
There's no downloaded
project. It needs to
download whole project
It can’t download part or fixed part in case
there is no downloaded project. In case of
this, download again. If this problem is
repeated, contact Customer Service Center.
0x10
XP Builder
Backup path is invalid.
Please check the path
that project is
downloaded.
When user change the storage location of
project data including image and font, if there
is not respective routine, it make newly. By the
way, download is stopped in case it fails to
make newly.
When it is designated as CF card, it can occur
in case CF card is not installed. If this problem
is repeated and not referred in the above,
contact Customer Service Center.

Other manuals for LSIS XP30-BTE