363-205-401 Power Up: DLP-509
Issue 7, March 1997 Page 3 of 4
10. Condition digital multimeter (DMM) to measure DC volts.
11. On
PRU
, connect DMM test leads to
48
jack and
FR GND
jack.
12. Does DMM indicate between 42 and 56 volts?
If
YES,
then proceed to Step
14.
If
NO,
then continue with Step
13.
13. Check wiring on power shelf between
336A RECTIFIER
and
PRU
using
SD-7C119-01. Repeat procedure from Step
11
after locating and correcting
trouble.
14. On
PRU
, connect DMM test leads to
20HZ
jack and
FR GND
jack.
Response: DMM indicates between 50 and 60 volts.
15. Leave DMM test leads connected to
20HZ
and
FR GND
jacks and condition
DMM to measure AC volts.
Response: DMM indicates between 90 and 110 volts.
16. Is AC/DC ringing voltages present at
20HZ
jack on the
PRU
?
If
YES,
then proceed to Step
18.
If
NO,
then continue with Step
17.
17. Check wiring on power shelf between
3C RINGING GENERATOR
and
PRU
using SD-7C119-01. Repeat procedure from Step
14
after locating and cor-
recting trouble.
18. Condition DMM to measure DC volts.
19. On
PRU
, connect DMM test leads to
+20HZ
jack and
FR GND
jack.
Response: DMM indicates between 50 and 60 volts.
20. Leave DMM test leads connected to
+20HZ
and
FR GND
jacks and condition
DMM to measure AC volts.
Response: DMM indicates between 90 and 110 volts.
21. Is AC/DC ringing voltages present at
+20HZ
jack on the
PRU
?
If
YES,
then
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
If
NO,
then continue with Step
22.
22. Replace
PRU
and repeat procedure from Step
2
.