EasyManua.ls Logo

Lucent Technologies SLC 5 Series - Page 131

Lucent Technologies SLC 5 Series
508 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Power Up: DLP-510 363-205-401
Page 4 of 4 Issue 7, March 1997
6.
NOTE:
Each 40D BFU fuse bead, except the yellow fuse beads, will pop out
when the fuse blows. The AUG11 ALM indicator light and the fuse flag
pops out when the fuse blows.
Do any fuses on
BFU
blow?
If
YES,
then continue with Step
7.
If
NO,
then proceed to Step
10.
7. Replace blown fuse(s) on
AUG11 BFU
using
WP90247 L201
Inser-
tion/Extraction tool; or
WECO 553A
Extractor Tool (Techni-Tool No.
594TE170) or
WECO 319B
(KS-6305) Extractor Tool (Techni-Tool No.
490PL020) for the
40D BFU
.
8. Do any fuses on
BFU
blow?
If
YES,
then continue with Step
9.
If
NO,
then proceed to Step
10.
9. Check wiring using SD-7C130-01 or SD-7C119-01.
10. Is another
BFU
to be installed at this time?
If
YES,
then continue with Step
11.
If
NO,
then
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
11. Repeat the procedure from Step
3
for next
BFU
to be installed.

Related product manuals