363-205-401 Power Up: DLP-532
Issue 7, March 1997 Page 3 of 4
7. Have all optical couplings been cleaned?
If
YES,
then proceed to Step
9.
If
NO,
then continue with Step
8.
8. Repeat Steps
6
and
7
for the next optical shelf slot to be equipped with an
AYB1B OU
.
9. Remove air tube from can of compressed air and store tube in J99409OB
case.
10. Store alignment card and handle in J99409OB case.
11. Remove protective cover from optical connector on each
AYB1B OU
.
12. Clean optical connector on each
AYB1B OU
using a Kimwipe wiper moist-
ened with alcohol. Dry the optical connector using compressed air.
13. Install each
AYB1B OU
into the prepared slots in the optical shelf.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.