RT Turn Up: DLP-505 363-205-401
Page 6 of 6 Issue 7, March 1997
26. Are switch settings on option switch correct?
If
YES,
then continue with Step
27.
If
NO,
then proceed to Step
29.
27. Get another
ADU
and set switches on option switch
S1
S2
according to work
order and Steps
4
and
8
.
28.
!
CAUTION:
Incorrectly set ADU option switches may result in immediate or future
loss of service or may introduce errors into the digital bitstream.
Insert
ADU
into
ADU
slot in bank being equipped.
Response: After approximately 15 seconds,
FAIL
,
MN
, and
NE
indica-
tors on
ADU
are lighted.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
29. Correct setting of switches on option switch and repeat from Step