363-205-401 RT Turn Up:
Issue 7, March 1997 Page 1 of 8
DLP-506
Option and Install AUB27 ADU
SUMMARY:
Set the ADU options for the system configuration (
S1
through
S11
) with
AB and CD set to preservice and unequipped (S1 positions 3-6). Install ADU, then
BCU and verify no alarms. Remove ADU and set AB (and CD if required) to
equipped (positions 2 and 3). Reinstall ADU and disregard alarms.
1. Has the
BCU
been installed?
If
NO,
then continue with Step
2.
If
YES,
then proceed to Step
12.
2. Get one
AUB27
(Feature Package B, Feature Package C-AutoCut, or Feature
Package F) and inspect for possible damage.
3. Verify that fuse on
ADU
is not blown. If fuse is blown, get another
ADU
that
contains good fuse.
4. On
AUB27 ADU
option switch
S1
(Figure 1 and Table A), use an orange stick
(KS-6320, L1) or equivalent and set switch positions as follows:
•
1
- Toward
PL
for protection switching or toward
NPL
for no protection
switching.
•
2
- Toward
2
if system is FPB Mode 2. Otherwise, set it toward
4
.
•
3
- Toward
ABP
.
•
4
- Toward
CDP
.
•
5
- Toward
ABU
.
•
6
- Toward
CDU
.
•
7
- Toward
1MJ
if MISC1 is to report a major alarm or toward
1MN
if
MISC1 is to report a minor alarm.
•
8
- Toward
2MJ
if MISC2 is to report a major alarm or toward
2MN
if
MISC2 is to report a minor alarm.