363-205-401 Conversions:
Issue 7, March 1997 Page 1 of 4
DLP-501
Install AUB26 Alarm Display Unit (ADU) for FPC
Conversion
1. Get one
AUB26
ADU
and inspect for possible damage.
2. Verify that fuse on
ADU
is not blown. If fuse is blown, get another
ADU
that
contains good fuse.
3. On
ADU
option switch
S1
(Figure 1), use orange stick (KS-6320, L1) or
equivalent to set switch positions
1
through
8
to agree with the settings of the
switch positions on switch
S2
(Figure 2) of the
ADU
removed previously. Set
switch position
9
to
D4
.
4.
!
CAUTION:
Incorrectly set ADU option switches may result in immediate or future
loss of service or may introduce errors into the digital bitstream.
Insert
ADU
into
ADU
slot.
Response: Disregard all indicators that may be lighted.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.