363-205-401 Conversions: DLP-506
Issue 7, March 1997 Page 3 of 6
3. On
ADU
option switch
S1
(Figure 1 and Table A) use an orange stick
(KS-6320, L1) or equivalent and set switches as follows:
•
1
- Toward
PL
(away from number) for protection switching. Toward
NPL
(toward number) for no protection switching.
•
2
- Toward
4
, unless FPB Mode 2 application is being equipped (toward
2
).
•
3
- Toward
ABI
(away from number).
•
4
- Toward
CDI
(away from number) if shelf group CD is being equipped.
•
5
- Toward
ABE
(away from number).
•
6
- Toward
CDE
(away from number) if shelf group CD is being equipped.
•
7
- This position is ignored for FPB applications. For C-AutoCut or other
applications, toward
MJ
if MISC1 is to report a major alarm or toward
MN
if MISC1 is to report a minor alarm.
•
8
- This position is ignored for FPB applications. For C-AutoCut or other
applications, toward
MJ
if MISC2 is to report a major alarm or toward
MN
if MISC2 is to report a minor alarm.
4. On
ADU
option switch
S2
(Figure 1), use an orange stick (KS-6320) or equiva-
lent and set switches as follows:
•
1 -
Toward
13
.
•
2 -
Toward
FS
for FPB (Feature Package B Mode 1 or Mode 2) applica-
tions. Toward
FE
for Feature Package C-AutoCut or other applications.
•
3 -
Toward
CUT
for Feature Package C-AutoCut applications. Toward
NC
for FPB or other applications.
• FPB Mode 2 must be set to NC for
ADU FAIL, MN, NE,
and
CMP
alarms
to clear.
•
4 -
Toward
DBL
.
•
5 -
Toward
NPA
.
•
6 -
Toward
MNP
.
•
7 and 8 -
Unused.
5. Set switch
S3
toward
DL
.
6. Set system identification rotary switches
S4
(most significant digit) through
S7
(least significant digit) to bank ID number.
7. Set rotary switches
S8
through
S11
to
0
.