363-205-401 Conversions: DLP-507
Issue 7, March 1997 Page 5 of 12
4. Is
LIU
an
AUA61B
,
AUA61C
or
AUA61D
?
If
YES,
then continue with Step
5.
If
NO,
then proceed to Step
7.
5. Set loopback enable/disable switch (
S700
or
S3
) to
ENB
if the channel bank is
connected to a DDM-1000 Multiplexer, otherwise, set it to the
DIS
position.
Proceed to Step
7.
6. Using orange stick (KS-6320, L1) or equivalent, set transmit and receive pad
switches on
LIU
per work order (Table B).
Table A
AUA61( )
LIU Equalizer Settings
Distance
to DSX-1
Equalizer Switch
(S400/S2) Setting
(Feet) 2 1 0
0-132
133-265
266-398
399-532
533-655
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
ON
OFF
ON
OFF
ON
Table B
AUA62( ) and AUA64( ) LIU Transmit/Receive Pad Setting
Inserted
Loss
Transmit Pad (S400/S1, S2)
Switch Settings
Receive Pad (S100)
Switch Settings
(dB) 1 2 3 4 1 2
22.5
15.0
7.5
0
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON*
ON*
OFF
* ON when depressed toward the numbers.