363-205-401 Conversions:
Issue 7, March 1997 Page 1 of 6
DLP-511
Install Line Switch Unit (LSU) in Facility Shelf
1.
NOTE:
An
AUA13 LSU
cannot be used in an RT channel bank assembly
equipped for FPD operation.
Get one
LSU
(Line Switch Unit) (
AUA13
or
AUA73
) and inspect for possible
damage.
2. Is the
LSU
an
AUA13
?
If
YES,
then proceed to Step
6.
If
NO,
then continue with Step
3.
3. Is
LSU
being installed in RT channel bank assembly equipped for FPD capa-
bility?
If
YES,
then continue with Step
4.
If
NO,
then proceed to Step
5.
4. Set switch
S2
located on the side of the
LSU
circuit pack (Figure 1) to position
32
and proceed to Step
6.
5. Set switch
S2
located on the side of the
LSU
circuit pack (Figure 1) to position
64
.
6. Set all eight force (
f
)/deny (
d
) switches on the
LSU
faceplate to off (right-hand
side) position (Figure 2).