363-205-401 Conversions:
Issue 7, March 1997 Page 1 of 2
DLP-518
Test Remote Miscellaneous Alarm (If Provided)
1. Is
MISC1
alarm assigned at the RT?
If
YES,
then continue with Step
2.
If
NO,
then
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
2. At RT, operate
MISC1
alarm.
Response: At
5ESS
switch MCC IDCU RT Page 188YZZ,X for 5E9(1)
generic or Page 1880,Y,ZZ,X for 5E9(2) generic (where
Y=IDCU, ZZ=TR303 RT number, X=SM number)
ENV1
and
MINOR
or
MAJOR
(depending on
ADU S1-7
setting) alarm
messages appear after about 30 seconds.
At RT,
BCU
indicator
MISC1
and
ADU
indicators
MJ
or
MN
(depending on
ADU S1-7
setting) light after about 30 sec-
onds.
3. At RT, cancel
MISC1
alarms.
Response: All alarms clear.
4. Is
MISC2
alarm assigned at the RT?
If
YES,
then continue with Step
5.
If
NO,
then
STOP. YOU HAVE COMPLETED THIS PROCEDURE.