Conversions: DLP-518 363-205-401
Page 2 of 2 Issue 7, March 1997
5. At RT, operate
MISC2
alarm.
Response: At
5ESS
switch MCC IDCU RT Page 188YZZ,X for 5E9(1)
generic or Page 1880,Y,ZZ,X for 5E9(2) generic (where
Y=IDCU, ZZ=TR303 RT number, X=SM number)
ENV2
and
MINOR
or
MAJOR
(depending on
ADU S1-8
setting) alarm
messages appear after about 30 seconds.
At RT,
BCU
indicator
MISC2
and
ADU
indicators
MJ
or
MN
(depending on
ADU S1-8
setting) light after about 30 sec-
onds.
6. At RT, cancel
MISC2
alarms.
Response: All alarms clear.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.