EasyManua.ls Logo

Lufft WS600-UBM - Page 106

Default Icon
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Manual Smart Weather Sensor
106 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
19.6.5.2 Buffer Assignment Additional Measurement Commands M2 / C2: Humidity
Device configured for measurement values in metric or US units:
Measurement Value
UMB
Channel
Min
Max
Unit
Buffer ‘0’
Rel. Humidity (act)
200
0.0
100.0
%
Rel. Humidity (min)
220
0.0
100.0
%
Rel. Humidity (max)
240
0.0
100.0
%
Rel. Humidity (avg)
260
0.0
100.0
%
Buffer ‘1’
Abs. Humidity (act)
205
0.0
1000.0
g/m³
Abs. Humidity (min)
225
0.0
1000.0
g/m³
Abs. Humidity (max)
245
0.0
1000.0
g/m³
Abs. Humidity (avg)
265
0.0
1000.0
g/m³
Specific Enthalpy (act)
215
-100.0
1000.0
kJ/kg
Buffer ‘2’
Mixing Ratio(act)
210
0.0
1000.0
g/kg
Mixing Ratio (min)
230
0.0
1000.0
g/kg
Mixing Ratio (max)
250
0.0
1000.0
g/kg
Mixing Ratio (avg)
270
0.0
1000.0
g/kg
Example: Request with M command
0M2!
00009<CR><LF>
0D0!
0+48.5+48.2+48.8+48.5<CR><LF>
0D1!
0+5.7+5.5+5.9+5.7+29.3<CR><LF>
Example: Request with C command
0C2!
000013<CR><LF>
0D0!
0+48.5+48.2+48.8+48.5<CR><LF>
0D1!
0+5.7+5.5+5.9+5.7+29.3<CR><LF>
0D2!
0+4.6+4.4+5.0+4.6<CR><LF>

Table of Contents

Related product manuals