19.6.5.4 Buffer Assignment Additional Measurement Commands M4 / C4: Wind
Device configured for measurement values in metric units:
Measurement Value
UMB
Channel
Min
Max
Unit
Buffer ‘0’
Wind Speed (act)
400
0.0
75.0
m/s
Wind Speed (min)
420
0.0
75.0
m/s
Wind Speed (max)
440
0.0
75.0
m/s
Wind Speed (avg)
460
0.0
75.0
m/s
Wind Speed (vct)
480
0.0
75.0
m/s
Buffer ‘1’
Wind Direction (act)
500
0.0
359.9
°
Wind Direction (min)
520
0.0
359.9
°
Wind Direction (max)
540
0.0
359.9
°
Wind Direction (vct)
580
0.0
359.9
°
Buffer ‘2’
Wind Direction corr. (act)
502
0.0
359.9
°
Wind Quality
805
0.0
100.0
%
Wind Chill Temperature (act)
111
-60.0
70.0
°C
Wind Speed Standard Dev.*
403
0.0
60.0
m/s
Wind Direction Standard Dev.*
503
0.0
359.9
°
Device configured for measurement values in US units:
Measurement Value
UMB
Channel
Min
Max
Unit
Buffer ‘0’
Wind Speed (act)
410
0.0
167.8
mph
Wind Speed (min)
430
0.0
167.8
mph
Wind Speed (max)
450
0.0
167.8
mph
Wind Speed (avg)
470
0.0
167.8
mph
Wind Speed (vct)
490
0.0
167.8
mph
Buffer ‘1’
Wind Direction (act)
500
0.0
359.9
°
Wind Direction (min)
520
0.0
359.9
°
Wind Direction (max)
540
0.0
359.9
°
Wind Direction (vct)
580
0.0
359.9
°
Buffer ‘2’
Wind Direction corr. (act)
502
0.0
359.9
°
Wind Quality
805
0.0
100.0
%
Wind chill Temperature (act)
116
-76.0
158.0
°F
Wind Speed Standard Dev.*
413
0.0
167.8
mph
Wind Direction Standard Dev.*
503
0.0
359.9
°
*) Note: Std.Dev. values will be available after the first request. See p. 11.