40 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
10.5.4 Eco-Mode 1
Eco Mode1 is an advanced energy saving mode.
Heating is only switched on when the following conditions are met:
The outside temperature is below the threshold temperature and precipitation was
detected. Heating then runs at the control temperature for 30 minutes (after the last
precipitation event).
When the outside temperature lies constantly below the threshold temperature and there
was no heating for more than 20h, heating is switched on for 30 minutes as a
precautionary measure in order to thaw any icing.
However, the precautionary 20h-heating only runs if the outside temperature was measured
at below the threshold temperature for the entire period and conditions were constantly
bright for at least 3 hours.
Setpoint Temp.: The heating controls at this temperature (in °C)
Heating mode1 Temp.: Threshold temperature (in °C) with effect from
which heating is enabled
Eco mode1 follow-up time: Follow-up time (in minutes)
Examples:
Outside temperature constantly below 5°C; no precipitation for more than 24h
Outside temperature constantly below 5°C; with precipitation