EasyManua.ls Logo

LUMENWERX VIA 2 User Manual

Default Icon
3 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SINGLE FIXTURE
CONTINUOUS SYSTEM
F
Remove the lenses (F) of all the fixtures in the run
with the included lens tool. If direct/indirect or
indirect, also remove the top lenses.
G
Disconnect LED molex connector (G) by taking a
pointed object and pressing on the two tabs on the
top.
G
H
Remove all the end LED cartridges (H). If direct/
indirect or indirect, also remove the top cartridge .
Lens
Tool
WWW.LUMENWERX.COM
www.lumenwerx.com (T) 514-225-4304 (F) 514-931-4862 © All rights are reserved to LumenWerx ULC. FILE NAME:VIA2-WALL-MOUNT-INST November 15, 2019 Page: 1 / 3
LumenWerx ULC. reserves the right to change or modify product specifications without notification
WALL MOUNT - INSTALLATION INSTRUCTIONS
VIA 2
NOTE: Wire dimming conductors as Class 1
1
4
2
5
3
6
Make wire connection between fixture (B) and
wall power cable (C). Number of wires may vary.
Insert fixture bracket (D) into wall bracket (A), and
secure in place with suplied screws (E).
A
B
A
C
A
E
D
SIDE VIEW
Locate wall bracket position using provided client
drawing. Install mounting brackets (A) to wall.
Align with structural stud (need double studs –
distance between screws is 1.250”) or use metal
anchors with min. length 1.250”. Flat head Philips
drive screw, nominal size #10, min. length 1.250”.
Question and Answer IconNeed help?

Do you have a question about the LUMENWERX VIA 2 and is the answer not in the manual?

LUMENWERX VIA 2 Specifications

General IconGeneral
CategoryRacks & Stands
ManufacturerLumenwerx
ProductVIA 2
MaterialAluminum
WheeledNo
ColorBlack

Summary

Single Fixture Installation

Wall Bracket Mounting

Locate wall bracket position using provided drawing. Install mounting brackets to wall using structural studs or metal anchors.

Wire Connection

Make wire connection between fixture and wall power cable. Number of wires may vary.

Fixture Bracket Securing

Insert fixture bracket into wall bracket and secure in place with supplied screws.

Continuous System Installation

Lens and Cartridge Removal

Remove lenses from all fixtures in the run. If direct/indirect, also remove top lenses.

LED Molex Connector Disconnection

Disconnect LED molex connector by pressing on the two tabs on top.

End LED Cartridge Removal

Remove all end LED cartridges. If direct/indirect, also remove top cartridge.

Fixture Joining

Join fixtures using align pins, secure with joiner screw, ensuring no wires are pinched.

Direct/Indirect Configuration

Top Joiner Securing

Secure the top joiner with screws, repeating on both sides.

LED Cartridge Reinstallation

Reinstall cartridge and reconnect LED molex connector, observing polarity for wires.

Lens Reinstallation

Put the lenses back in place after all internal connections are made.