EasyManua.ls Logo

Luowei OILFREE COMPRESSOR - HOW TO SET UP YOUR UNIT; Electrical Circuit Protection

Luowei OILFREE COMPRESSOR
10 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HOW TO SET UP YOUR UNIT
Locate the air compressor in a clean, dry and well ventilated area. The air
compressor should be located at least 12" away from the wall or other
obstructions that will interfere with the flow of air. The air compressor pump
and shroud are designed to allow for proper cooling. The ventilation openings
on the compressor are necessary to maintain proper operating temperature.
Do not place rags or other containers on or near these openings. The air filter
must be kept clear of obstructions which could reduce air flow to air
compressor.
Extension Cord
Use extra air hose instead of an extension cord to avoid voltage drop and
power loss to the motor, and to prevent overheating. If an extension cord must
be used, be sure it is:
Voltage and circuit protection
Refer to the Parts Manual for the voltage and minimum branch circuit
requirements.
Certain air compressors can be operated on a 15 amp circuit if the following
conditions are met.
1. Voltage supply through branch circuit is 15 amps.
2. Circuit is not used to supply any other electrical needs (lights, appliances,
etc.)
3. Extension cords comply with specifications.
4. Circuit is equipped with a 15 amp circuit breaker or 15 amp time delay fuse.
NOTE: If compressor is connected to a circuit protected by fuses, use only
time delay fuses.
If any of the above conditions cannot be met, or if operation of the compressor
repeatedly causes interruption of the power, it may be necessary to operate it
from a 20 amp circuit. It is not necessary to change the cord set.