5186767-LTG-B-0816
2 Johnson Controls Unitary Products
LIST OF SECTIONS
DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
PHYSICAL AND ELECTRICAL DATA . . . . . . . . . . . . . . . . . . . . . . . 3
DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SYSTEM CHARGE FOR VARIOUS MATCHED SYSTEMS . . . . . . . 4
COOLING CAPACITY - With Air Handler Coils . . . . . . . . . . . . . . . 5
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces
and Coils (Coil Only Ratings) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
COOLING CAPACITY - With High Efficiency Motor Furnaces . . . 9
ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
SOUND POWER RATINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
MECHANICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . 41
TYPICAL INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
TYPICAL FIELD WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
ALTERNATIVE INSTALLATION CLEARANCES . . . . . . . . . . . . . . 43
PERFORMANCE DATA - 1.5 TON . . . . . . . . . . . . . . . . . . . . . . . . . 44
PERFORMANCE DATA - 2 TON . . . . . . . . . . . . . . . . . . . . . . . . . . 47
PERFORMANCE DATA - 2.5 TON . . . . . . . . . . . . . . . . . . . . . . . . . 51
PERFORMANCE DATA - 3 TON . . . . . . . . . . . . . . . . . . . . . . . . . . 55
PERFORMANCE DATA - 3.5 TON . . . . . . . . . . . . . . . . . . . . . . . . . 60
PERFORMANCE DATA - 4 TON . . . . . . . . . . . . . . . . . . . . . . . . . . 64
PERFORMANCE DATA - 5 TON . . . . . . . . . . . . . . . . . . . . . . . . . . 68
NOMENCLATURE
BRAND
T
C = Coleman
T = Factory Branded
PRODUCT TYPE
C
C = Air Conditioner (US Northern or
Southeast Region)
H = Heat Pump
F = Fin & Tube Air Conditioner
W = High EER US Southwest Region
Air Conditioner
NOMINAL
SERIES EFFICIENCY
AND STAGING
7
3 = 13 SEER / 1-Stage (US Northern
Region)
4 = 14 SEER / 1-Stage (US Southeast
or Southwest Region)
7 = 17 SEER / 1-Stage
REFRIGERANT
B
B = R-410A
NOMINAL
UNIT CAPACITY
(MBH)
36
18 = 1.5 Ton 42 = 3.5 Ton
24 = 2 Ton 48 = 4 Ton
30 = 2.5 Ton 60 = 5 Ton
36 = 3 Ton
VOLTAGE
(Voltage-Phase-Hertz)
2
2 = 208/230-1-60
GENERATION
(MAJOR REVISION)
1
1 = 1st Gen
2 = 2nd Gen
etc
FACTORY OPTION
S
S = Standard (No Options)
H = Hard Start Kit
STYLE LETTER
(Minor Revision)
Not Used for Ordering
A
A = Style A
B = Style B