WP SERIES PUMPS
Installation diagram
Remark:WP200-II WP250-II & WP300-II with 2 speed
V/Hz esp: See pump nameplate. liquid temperature:4 C ~ 50 C
Storage temperature: -10 C ~ +50 C. Relative Air Humidity:95% Max.
oo
oo
-1-
-4-
140
235
90
170
195
71
71
125 195
L
Edition :2007-05 2
2FBT
2FBT
Power(P )
1
Model
kW
HP
Hmax
(m)
maxQ
(L/min)
WP300-I
WP200-I
WP250-I
L
620
14
670
16
1.50
2.0
414
1.85 2.5
730
18
414
2.20 3.0
414
WP300-II
WP200-II
WP250-II
620
14
670
16
730
18
(Low speed) 0.35
(high speed) 1.50
3/8
2.0
431
(Low speed) 0.40
(high speed)1.85
2.5
1/2
431
(Low speed) 0.45
(high speed)2.20
3.0
5/8
431
1.General
These instructions are for correct installation, and optimum performance of the Bath pumps, so they should be
read carefully. These are single-stage centrifugal pumps designed to operate with compact hydromassage
equipment, They are equipped with a total-emptying system to prevent the discharge of residual liquid in each
stopping.
These units are designed to operate with clean water at a maximum water temperature of 50 C.
Correct installation is ensured by following these instructions and those of the wiring diagram; otherwise, over
loads may be produced in the motor. We decline responsibility for any damage caused by not following these
instructions..
O
Built of top quality materials, they are subjected to strict hydraulic and electrical controls and are carefully verified.
202
INSTRUCTION MANUAL
When installing and using this electrical equipment, basic safety
precautions should always be followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS
1.READ AND FOLLOW ALL
INSTRUCTIONS
2.WARNING
3.WARNING
4.CAUTION
To reduce the risk of injury.
do not permit children to use this product
unless they are closely supervised at all
times.
Risk of Electrical Shock.
Connected only to grounding type rece-
ptacle protected by a ground fault circuit
interrupter(GFCI). Contact a qualified
electrician if you cannot verify that the
receptacle is protected by GFCI.
Do not bury cord. Locate
cord to minimize abuse from lawnmowers,
hedge trimmers, and other equipment.
5.CAUTION
6.WARNING
In case the running
parts will injure people, don't make
the electric pump
pipeline have been connected.
To reduce the risk of
electrical shock, replace damaged
cord immediately.
running before then
To reduce the risk of
cord
a properly located outlet.
9 Do not install within an outer encl-
unless so marked.
T
Young children should be supervi-
sed to ensure that they do not play with
the appliance.
7.WARNING
8.CAUTION
.
10.
11.
13.SAVE THESE INSTRUCTIONS
electrical shock, do not use extension
to connect unit electric supply;
provide
Jetpump for jetted bathtubs,
spapools, swimmingpools, massage
stations, cleaning system.
osure or beneath the skirt of a hot tub
his appliance is not intended for use
by young children or infirm persons unless
they have been adequately supervised by
a responsible person to ensure that they
can use the appliance safely.
12.FOR INDOOR USE ONLY.
POOL AND SPA PUMP
Question and Answer IconNeed help?

Do you have a question about the LX WP Series and is the answer not in the manual?

Summary

Important Safety Instructions

General Safety Precautions

Covers critical safety warnings for electrical shock, installation, and proper usage by children and infirm persons.

Installation and Operation

General Product Description

Describes the pumps as single-stage centrifugal units with total-emptying systems for hydromassage applications.

Installation Guidelines

Details requirements for horizontal mounting, securing, suction/discharge pipe length, and ensuring rating labels are visible.

Pipe Assembly

Provides guidance on pipe diameter, avoiding traps, preventing pipe contact with the pump, and proper sealing.

Electrical Connection

Outlines electrical installation requirements, including separation systems, RCD protection, cable standards, and earth connection.

Pre-Start-up Checks

Specifies checks for free shaft rotation, mains voltage/frequency, and preventing dry operation.

Start-up Procedure

Instructs on electrically starting the pump only after pipes are connected and checking for obstacles.

Maintenance and Troubleshooting

Maintenance and Cleaning

Recommends cleaning and dry storage for idle pumps and outlines a procedure for cleaning the pump via the bathtub.

Troubleshooting Guide

Lists common pump symptoms like 'No Turn' or 'Not Pumping Properly' with possible causes and checks.

LX WP Series Specifications

General IconGeneral
Power SourceElectric
DimensionsVaries by model
InputVaries by model
Voltage115V/230V (single phase) or 230V/460V (three phase)