3.11 Siren/Strobe Unit (to be purchased separately)
Fit the external siren as detailed in its own installation manual, but wire it as detailed below
CONTROL UNIT SIREN UNIT
STB TRIGGER─────────────Æ - STB
BELL TRIGGER─────────────Æ - TG
BELL TAMPER (left) ───────ÆRETURN
+ AUX────────────────Æ + HOLD
- AUX─────────────────Æ - HOLD
NB Only five of the six coloured wires are used.
3.12 Testing Siren/Strobe
You can now test the operation of the Siren/Strobe Unit. Proceed as follows:
a. Turn on mains power to the Control Unit; the unit will beep twice, the display will show , and
the “Mains” LED will be on. You may notice that the display flicker slightly, this is not a fault but
indicates that the Control Unit is functioning correctly.
b. To test the siren, press keys as follows:
Press ,display changes to flashing.
Press ,display changes to .
Press ,display changes to and sirens sound (internal & external).
Press ,sirens stop sounding.
c. To test the siren, press keys as follows:
Press ,display changes to flashing.
Press ,display changes to .
Press , display changes to and strobe flashes.
Press ,strobe stop flashing.
3.13 Installing the Rechargeable Battery (To be purchase separately)
Illustration 12
a. Turn off mains power to the control unit and open the front cover.
b. Locate the red and black flying leads with spade connectors attached.
c. Push the spade connector firmly over the terminals on the battery, fitting the black (negative)
connector first. Warning – Observe Polarity! When both terminals are connected the internal
control unit tamper alarm will sound – ignore this for now. Place the battery into the control unit,
close the front cover and replace the fixing screw.
d. To silence the tamper alarm, enter and the display showing (to indicate
Control Unit tamper). Press ,the display reverts to with the system in “Standby” mode.
e. Turn on mains power to the control unit. Note that if the control unit is operating from the
rechargeable battery only for more than a few seconds, the “Mains” light will flash.
This complete the basic installation of your system. If required, you may wish to set up some of the
system parameters (e.g. siren time) as shown in Section 5.
1432
Program
4
RESET
Program
1432
RESET
5
1432
RESET