Section 6 – Engineer Programming
The pin code functions are used for advanced programming of the control unit. This section will
explain in detail the purpose of the functions and how to program each one of them.
The factory default engineer code is .
6.1 Setting new Engineer Code
The engineer code is factory set to and is the same for every LS5000 system.
It is recommended that the engineer code be changed immediately after completing the basic
installation.
Press the following buttons:
Press ,display changes to flashing.
Press ,display changes to .
Press ,display changes to for 2 seconds, then to four-bar pattern , to show
that four digits need to be entered.
Enter your desired 4 digit engineer code:
Enter your desired 4 digit engineer code. For each digit you press, one of the lighted bars
on the four-bar pattern will go out. After pressing the fourth digit, unit gives beep.
Press ,Control Unit stores the new engineer code.
or
Press ,this cancels the above procedure and returns the control unit to display .
Note that the old engineer code will work until the new engineer code has been entered to certify
new code. When certified, the old code is deleted. You can use this procedure whenever you wish to
change your engineer code. Note that the engineer code cannot be the same pincode as the user or
secondary code.
6.2 Setting Walk-through Zones
The walk-through zones are detectors, which you can trigger during the entry time (after activating
the entry zone). You can program each detector to be a walk-through zone, but it is recommended to
set the walk-through zones, only on the detectors that are being triggered during the entry or exit
time.
Press ,display changes to flashing.
Press ,display changes to .
Press ,display shows .
Press until the required zone is displayed.
Press ,to set walk-through ON, display shows the zone number is flashing.
or
Press ,to set walk-through OFF, display shows the zone number is steady.
Press again and proceed as above until all required walk-through zones are
programmed.
Press ,to retain walk-through setting.
Or
Press ,to return display shown Standby” mode and without retaining recent
walk-through settings.
1 11 1
1 11 1
Program
1 11 1
99
n nnn n
Store
RESET
Program
1 11 1
19
Display
1
0
Display
Store
RESET