Lynx L15ICE 10
Electrical Connecons
L15ICE
FINAL CHECKLIST
1. Is the icemaker level?
2. Have all shipping tape, string and packing material been removed from the icemaker?
3. Are all components, fasteners and thumbscrews securely in place?
4. Have all electrical and piping connecons been made?
5. Has power supply voltage been tested of checked against the nameplate rang? Has a proper ground been in-
stalled to the icemaker?
6. Are the water supply line shut-o valve and drain valve installed? Has the water supply pressure been checked to
ensure a minimum of 10 PSIG (0.7 bar) and a maximum of 113 PSIG (7.5 bar)?
7. Have the compressor hold-down bolts and all refrigerant lines been checked against vibraon and possible failure?
8. Has the bin control thermostat been checked for correct operaon? When the icemaker is running, hold an ice cu-
be in contact with the bulb. The icemaker should stop within 3-10 seconds.
9. Has the user been given the instrucon manual and instructed on how to operate the icemaker and the im-
portance of the recommended periodic maintenance?
10. Has the user been given the name and telephone number of an authorized service agent?
WARNING: THIS APPLIANCE MUST BE GROUNDED.
This icemaker requires a ground that meets naonal and local electrical code requirements. To prevent possible severe
electrical shock injury to individuals or extensive damage to equipment, install a proper ground wire to this icemaker.
Remove the plug from the electrical outlet before any maintenance, repairs, or cleaning is undertaken.
This icemaker must be plugged into a separated power receptacle which has enough capacity. The
maximum allowable voltage variaon should not exceed ± 10% of the nameplate rang. See the
nameplate for details.
An electrical permit and services of a licensed electrician are oen required.