47LV
P. 1 / 18EM-9502-B Rev.3
DC INPUT DIGITAL PANEL METER
(4 1/2 digit, LED display type)
MODEL
47LV
OPERATING MANUAL
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
PACKAGE INCLUDES:
Digital panel meter ...................................................... (1)
Engineering unit sticker label sheet ........................... (1)
MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
OPERATING MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection, ba-
sic maintenance procedures and detailed operations.
2.00 marked parameters are usable with the product ver-
sion 2.00 or higher.
POINTS OF CAUTION
CONFORMITY WITH EC DIRECTIVES
• This equipment is suitable for Pollution Degree 2 and In-
stallation Category II. Reinforced insulation (input or DC
output to alarm output to power: 300V) and basic insula-
tion (input to DC output: 300V) are maintained. Prior to
installation, check that the insulation class of this unit
satisfies the system requirements..
Altitude up to 2000 meters
The equipment must be installed such that appropriate
clearance and creepage distances are maintained to con-
form to CE requirements. Failure to observe these re-
quirements may invalidate the CE conformance.
In order to enable the operator to turn off the power input
immediately, install a switch or a circuit breaker accord-
ing to the relevant requirements in IEC 60947-1 and IEC
60947-3 and properly indicate it.
POWER INPUT RATING & OPERATIONAL RANGE
Locate the power input rating marked on the product and
confirm its operational range as indicated below:
100 – 240V AC rating: 85 – 264V, 50/60 Hz, approx. 6.5VA
24V DC rating: 24V ±10%, approx. 3W
110V DC rating: 85 – 150V, approx. 3W
GENERAL PRECAUTIONS
Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
Be sure to put the terminal cover on while the power is
supplied.
ENVIRONMENT
Indoor use
When heavy dust or metal particles are present in the air,
install the unit inside proper housing with sufficient ven-
tilation.
Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
Be sure that the ventilation slits are not covered with ca-
bles, etc.
REQUIREMENTS TO ENSURE IP 66
Observe the designated panel cutout size (W92 × H45
mm).
The watertight packing included in the product package
must be placed behind the front cover.
Both mounting brackets must be fastened tightly until
they hit the panel.
Conrm visually that the packing is not contorted or ex-
cessively run off the edge after installation.
WIRING
Make sure for safety that only qualied personnel per-
form the wiring.
Do not install cables (power supply, input and output)
close to noise sources (high frequency line, etc.).
Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
AND ....
The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for sat-
isfying complete performance described in the data sheet.

Other manuals for M-system 47LV

Question and Answer IconNeed help?

Do you have a question about the M-system 47LV and is the answer not in the manual?

Summary

POINTS OF CAUTION

Conformance and Environmental Requirements

Ensures compliance with EC directives and specifies environmental operating conditions.

Power Input and Operational Range

Defines the acceptable input voltage, frequency, and power consumption limits.

General Safety Precautions

Highlights essential safety measures to prevent injury or equipment damage during operation.

Wiring Guidelines

Provides instructions for safe and reliable electrical connections to prevent noise interference.

INSTALLATION

Panel Cutout and Mounting

Details the required panel opening dimensions and the procedure for mounting the unit.

TERMINAL CONNECTIONS

Unit Dimensions

Presents the external physical measurements of the panel meter unit.

CONNECTION DIAGRAM

Alarm Output Configurations

Describes different alarm suffix codes and their corresponding N.O. or SPDT contact outputs.

Terminal Block Details

Explains the structure and removal of the terminal block for wiring connections.

SETTING PROCEDURE

Initial Setting Flowchart

Outlines the step-by-step process for the initial configuration of the panel meter.

General Setting Flowchart

Illustrates the procedure for performing various settings after initial setup.

OPERATIONS IN MEASURING MODE

Displaying Max;Min Values

Explains how to switch the main display between current, maximum, and minimum measured values.

Forced Zero Operation

Details the procedure for setting the current measurement reference point to zero.

Confirming Alarm Setpoints

Describes how to view the configured alarm setpoints (LL, L, H, HH) on the display.

SETTING MODE OPERATIONS

Parameter Navigation

Explains how to move between different parameters and setting items in setting modes.

Parameter Editing

Details the process of changing parameter values using the unit's buttons.

Error Handling

Covers methods for recovering from setting errors and invalid parameter entries.

Teach Calibration

How to Teach Input Values

Provides step-by-step instructions for performing zero and span calibration.

LOOP TEST OUTPUT MODE

ERROR MESSAGES

M-system 47LV Specifications

General IconGeneral
BrandM-system
Model47LV
CategoryMeasuring Instruments
LanguageEnglish