72
Diode Test
Range Description Remark
2.000V
The approximate forward
voltage drop of the diode is
shown on the display.
Open Circuit Voltage: about 3V dc
Test Current: about 0.24mA
Continuity Test
Description Remark
The buzzer will sound when the resistance is less than about 40Ω.
The buzzer will not sound when the resistance is more than 150Ω.
The buzzer may or may not sound when the resistance is between
40Ω and 150Ω.
Open Circuit Voltage:
about 3V dc
Capacitance
Range Resolution Accuracy
1µF 0.001µF
± (2.0% + 5)
10µF 0.01µF
100µF 0.1µF ± (3.0% + 5)
1,000µF 1µF ± (5.0% + 5)
Note:
Accuracy is for capacitors that have negligible dielectric absorption.
Temperature
Range Resolution Accuracy
-40°C to 0°C 0.1°C ± (4.0°C + 3 digits)
0°C to 400°C 0.1°C ± (2% + 3°C)
1°C ± 3.0% of reading
-40°F to 0°F 0.1°F
0°F to 400°F 0.1°F ± (2% + 5.4°F)
400°F to 2,498°F 1°F
± (7.2°F + 3 digits)
Use K type thermocouple.
Note:
1. Accuracy does not include error of the thermocouple probe.
2. Accuracy specication assumes ambient temperature is stable to ±1°C. For ambient temperature changes
of ±5°C, rated accuracy applies after 1 hour.
± 3.0% of reading