JSTT1000 4 6/3/15
PREVENTATIVE MAINTENANCE
TROUBLESHOOTINg
1. Always store the jack in a well protected area where it will not be exposed to inclement weather, corrosive vapors, abrasive dust, or any other harmful
elements. The jack must be cleaned of water, snow, sand, grit, oil, grease or other foreign matter before using.
2. Lubricate moving parts, excluding the telescopic rams, monthly with a general purpose grease.
IMPORTANT: Any jack found to be defective as a result of worn parts due to insufficient or lack of lubrication is not eligible for warranty consideration.
3. It should not be necessary to refill or top off the reservoir with hydraulic fluid unless there is an external leak. An external leak requires immediate repair
which must be performed in a dirt-free environment by qualified hydraulic repair personnel who are familiar with this equipment.
In order to prevent seal damage and jack failure, never use alcohol, hydraulic brake fluid or transmission oil in the jack.
Use Chevron Hydraulic Oil ISO 32 or its equivalent Unocal Unax AW150, or hydraulic jack oil.
4. Everyjackownerisresponsibleforkeepingthejacklabelscleanandreadable.Useamildsoapsolutiontowashexternalsurfacesofthejackbutnot
any moving hydraulic components.
5. Donotattempttomakeanyhydraulicrepairsunlessyouareaqualiedhydraulicrepairpersonthatisfamiliarwiththisequipment.Repairsmustbe
performed by an authorized service center.
JSTT1000
1000-LBS. CAPACITY
TRANSMISSION JACK - 2 STAGE
PROBLEM ACTION
1.Unitwillnotliftratedload. PurgeairfromhydraulicsystembyfollowingprocedureunderSETUP.
2.Unitwillnotsustainratedloadorfeels“spongy”underratedload. Purge air from hydraulic system as above.
3.Unitwillnotlifttofullheight. Purge air from hydraulic system as above.
4. Handle tends to raise up while the unit is under rated load. Pump the handle rapidly several times to push oil past ball valves in power unit.
5.Unitstilldoesnotoperate. Contact your Mac Tools Distributor.
Failure to follow these Preventative Maintenance instructions may result in serious injury or death, and/or property damage.
WARNING
WARNING