EasyManua.ls Logo

MAC 6000 - (5) Checking and adjusting cooling fan V-belt (2 nd time and after)

MAC 6000
176 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
131
MAC 6000 Hydronic Heater
Generator
2106 East Indiana Ave., Bismarck, ND 58504 U.S.A. • www.macheaters.com • +1-800-272-4604
ECP3 Manual - March 2013 rev. 03
16
Ricordarsi che, una volta che il generatore
sara‟ accoppiato al motore primario, o
montato su un basamento, o installato in un
telaio in modo da formare un corpo unico,
non dovra piu‟ essere sollevato dai propri
golfari ma si dovranno seguire le indicazioni
dell‟installatore.
Non disperdere l‟imballo nell‟ambiente, ma
rivolgersi alle agenzie di smaltimento.
TRASPORTO E
IMMAGAZZINAMENTO
ACCOPPIAMENTO
MECCANICO
L‟accoppiamento del generatore al motore
primo e a cura dellutilizzatore finale ed e
eseguito secondo la sua sola discrezione.
Le attenzioni richieste sono:
NELLA MESSA IN SERVIZIO AVER CURA
CHE LE APERTURE DI ASPIRAZIONE E
SCARICO DELLARIA DI RAFFREDDA-
MENTO SIANO SEMPRE LIBERE.
IL LATO DI ASPIRAZIONE NON DEVE ES-
SERE VICINO A SORGENTI DI CALORE.
IN OGNI CASO, SE NON SPECIFICATA-
MENTE CONCORDATO, LA TEMPERA-
TURA DELLARIA DI RAFFREDDAMENTO
DEVE ESSERE QUELLA AMBIENTE E
COMUNQUE NON SUPERIORE A 40°C.
IN CASO DI GENERATORI MONO-
SUPPORTO IN FASE DI ACCOPPIA-
MENTO CON IL MOTORE PRIMO,
FARE ATTENZIONE CHE IL ROTO-
RE NON SI SFILI; TOGLIERE IL SI-
STEMA DI FISSAGGIO ROTORE.
TRANSPORT AND
STORAGE
Once the generator is coupled with an engi-
ne, mounted on a baseframe, or installed on
a complete generating set, it cannot be lifted
by its lifting bolts.The relevant instructions for
lifting complete generating set should be fol-
lowed.
Any packing materials should be disposed of
via correct waste disposal methods. Do not
discard waste materials into the environment.
MECHANICAL
COUPLING
The mechanical coupling is under the sole
responsibility of the final user, and has to be
done at his discretion.
Warnings:
BEFORE STARTING THE ALTERNATOR,
CHECK THAT THE AIR INLETS AND OUT-
LETS ARE FREE OF ANY OBSTRUC-
TIONS.
THE AIR INLETS SHOULD NOT BE NEAR
ANY HEATING SOURCES.
IN ANY CASE, IF NOT SPECIFICALLY RE-
QUESTED, THE COOLING AIR TEMPE-
RATURE MUST BE EQUAL TO THE ENVI-
RONMENT TEMPERATURE AND NEVER
HIGHER THAN 40°C.
BEFORE MECHANICAL COUPLING
OF SINGLE BEARING ALTERNA-
TORS REMOVE THE ROTOR SECU-
RING DEVICE PLACED THERE TO
PREVENT ROTOR FROM SLIPPING.
IMPORTANTE
IMPORTANT
WICHTIG