CLEANING
Unplug your appliance and remove any products to a suitable back-up showcase before cleaning.
Take out all removable parts before cleaning.
Clean the inner compartment (10), equipment parts and casing (9) with dry cloth. Do not allow the control panel (7), power cord with plug (5), ventilation
opening (1), lamp (8) or other electrical components to become wet.
Never use corrosive detergents, wire brushes, or abrasive scourers to clean your appliance.
Never use metal or sharp implements to remove debris.
Dry all surfaces thoroughly.
Use dry cloth to clean the gaskets and seals. Check them for debris to ensure the door (2) always closes properly.
Do not remove or damage the rating label as it contains important data.
Replacing the lamp
Please do not replace the lamp (8) yourself. Contact qualified personnel for this purpose.
Note: the specification of replacement lamp should be the same as the original one.
DISPOSAL INSTRUCTIONS
Disposal of old appliances
Disable discarded appliances by removing the plug and cutting through the power cord.
Break any locks in order to avoid children and other persons becoming trapped. If possible, remove any doors and discard separately.
Warning - hazardous chemicals! Do not allow children to play with the old appliance.
Do not damage the refrigerant circuit during storage and transportation of old appliances! Make sure that the evaporator pipes, refrigerant circuit
and surface coverings are not damaged. Avoid contact with the eyes as the refrigerant may cause serious eye injury.
Do not store old appliance near heat and ignition sources. In event of leakage the refrigerant of this appliance is highly inflammable.
Please note: the refrigeration system contains gases and refrigerants which require specialist waste disposal.
Disposal of packaging
All packaging materials should be disposed of in an environmentally friendly way.
The cardboard may be used as scrap paper. The protective foil and the foam cushions are CFC – free.
Do not allow children to play with the packaging and destroy plastic bags safely.
You can break or cut the cardboard into smaller pieces and give to a waste paper disposal service.
Environmental Protection
Discarded electric appliances are recyclable and should not be discarded in the domestic waste! Please actively support us in conserv-
ing resources and protecting the environment by returning this appliance to the collection centres.
TECHNICAL DATA
Model GBC1001 /
GBC1001S
GBC1002 /
GBC1002S
GBC1003 /
GBC1003S
GBC1102 GBC1103
Rated Voltage 220 - 240 V
~
Rated Frequency 50 Hz
Climate Class 4
Protection Class I
Temperature 0 to +8°C
Foam Blowing Agent C-pentane
Rated Current 1.25 A 1.66 A 1.66 A 1.66 A 1.76 A
Energy
Consumption
2.18 KWh/24h 2.60 KWh/24h 3.78 KWh/24h 3.78 KWh/24h 4.76 KWh/24h
Refrigerant R600a (35 g) R600a (62 g) R600a (85 g) R600a (64 g) R600a (90 g)
Light 7 W 7 W 9 W 7 W 9 W
Net Volume 128 L 200 L 312 L 200 L 312 L
Net/
Gross Weight
48/58 kg (GBC1001)
51/61 kg (GBC1001S)
62/72 kg (GBC1002)
65/75 kg (GBC1002S)
86/96 kg (GBC1003)
89/99 kg (GBC1003S)
65/75 kg 86/96 kg
Dimension
(W x H x D)
600 x 925 x
540 mm
900 x 925 x
540 mm
1350 x 925 x
540 mm
900 x 925 x
540 mm
1350 x 925 x
540 mm
Noise Level
60 dB(A) 67 dB(A) 67 dB(A) 56 dB(A) 56 dB(A)
GB