Magellan 7
System Options
[090] General Options Bold = Default setting
Option OFF ON
[1] Access code length 6 digits 4 digits
[2] Audible trouble warning (except AC power failures) Disabled Enabled
[3] Lock master code Disabled Enabled
[4] Use user code 16 as duress code Disabled Enabled
[5] Console tamper supervision Disabled Enabled
[6] Need code to bypass zones Disabled Enabled
[7] PGM1 normal state N.O. N.C.
[8] PGM2 normal state N.O. N.C.
[091] General Options Bold = Default setting
Option OFF ON
[1] Panic 1 (Emergency) Disabled Enabled
[2] Panic 2 (Auxiliary) Disabled Enabled
[3] Panic 3 (Fire) Disabled Enabled
[4] Panic 1: Silent or audible alarm Silent Audible
[5] Panic 2: Silent or audible alarm Silent Audible
[6] Panic 3: Silent or audible alarm Silent Audible
[7] PGM1 used as (MG-6160 only) Direct output X10 output 7
[8] PGM2 used as (MG-6160 only) Direct output X10 output 8
[092] Arming/Disarming Options Bold = Default setting
Option OFF ON
[1]
Auto-arm on time (
)
Disabled Enabled
[2] Auto-arm on no movement † Disabled Enabled
[3] Auto-arm in what arming mode † Regular Stay
[4] Switch to Stay arming if no entry delay is opened Disabled Enabled
[5] Regular arming switches to Force arming † Disabled Enabled
[6] Stay arming switches to Force arming † Disabled Enabled
[7] One-touch Regular/Force arming † Disabled Enabled
[8] One-touch Stay arming Disabled Enabled
† Force arming and Auto-arming are not for use in UL installations.
[093] Arming/Disarming Options Bold = Default setting
Option OFF ON
[1] Future use Future use Future use
[2] Future use Future use Future use
[3] Bell squawk when arming/disarming with remote control * Disabled Enabled
[4] No exit delay when arming with remote control Disabled Enabled
[5] Report system disarming Always After alarm only
[6] Exit delay termination Disabled Enabled
[7] Follow zones become Entry Delay 2 zones when Delay zone is
bypassed
Disabled Enabled
[8]
FM tuner ON when system is armed (
) (MG-6160 only)
Disabled Enabled
* Bell Squawk on Arm must be enabled for UL installations.