Do you have a question about the Majestic 400DVB and is the answer not in the manual?
Crucial safety warnings and guidelines for safe operation and installation of the fireplace.
Information on CSA testing and compliance with standards for direct vent gas fireplace heaters.
Details the specifications of the appliance, including gas compatibility and installation approvals.
Specifies the inlet and manifold pressure requirements for natural and propane gas.
Lists the gas input ratings and corresponding orifice sizes for different models.
Provides guidance on installation derating and requirements for high altitude installations.
A detailed table showing the physical dimensions for each fireplace model.
Essential checks and items required before commencing installation.
A list of tools and materials necessary for the installation process.
Instructions and considerations for building the firebox frame according to dimensions.
Recommendations for insulating the appliance and surrounding chase in cold climates.
Key considerations for choosing the optimal location for the fireplace installation.
Illustrates various possible installation locations for the fireplace.
Specifies the mandatory minimum clearances required between the appliance and combustible materials.
Details the required clearances for installing a mantel above the fireplace.
Guidelines for selecting and applying noncombustible finishing materials around the fireplace.
Instructions for converting the appliance from rear vent to top vent configuration.
Essential precautions and safety rules for installing the venting system.
Specifies required clearances from vent pipes to combustible materials.
Guidance on planning the vent installation, including horizontal and vertical termination.
Instructions for installing the vent system within an external chase structure.
Tables detailing required clearances for vent termination locations in Canada and the US.
Specifies clearances for vent terminations near building features like corners and balconies.
Instructions on interpreting the vent graph for determining vertical and horizontal vent run relationships.
Instructions for venting the appliance through a rear wall termination.
Details hole sizes and framing requirements for different exterior wall types.
Explains limitations and configurations for horizontal vent termination setups.
A graph illustrating the relationship between vertical and horizontal dimensions for rear wall venting.
Guidelines for maximum horizontal vent pipe length without vertical rise.
Details how elbows affect the maximum allowable horizontal vent run length.
Illustrates how different elbow configurations impact the maximum vent run.
Specific instructions and recommendations for installing vent terminals below ground level.
Guidelines for using support straps for horizontal vent pipe runs.
Instructions for installing the venting system vertically through the roof.
Steps for routing vertical venting, including offsets and restrictor disk use.
Procedures for cutting and framing holes in ceilings for vertical vent installation.
Instructions for installing firestops in framed ceiling openings for safety.
Specific steps for installing the vent system through a cathedral ceiling.
Illustrates how to connect flexible venting to the appliance starting collar.
Guidelines for routing flexible vent pipe, including clearances and minimum bend radius.
Procedures for connecting flexible vent to vertical termination components.
Steps for connecting flexible vent to horizontal termination components.
Emphasizes verifying the gas type before installation to prevent compatibility issues.
Guides the connection of gas piping to the fireplace and burner system.
Details requirements for gas line connections, including shutoff valves and sealant.
Recommends and illustrates the installation of a sediment trap/drip leg in the gas supply line.
Procedures for checking and adjusting gas pressures at the valve for millivolt and electronic systems.
General guidelines and warnings for electrical connections, emphasizing safety and code compliance.
Wiring diagram and instructions for installing an optional remote wall switch.
Wiring diagram for the electronic pilot ignition system, including the ignition module.
Instructions for connecting optional DC remote control systems.
Illustrates the wiring connections for the optional fan/blower system.
Critical safety warnings and procedures to follow before attempting to light the pilot or burner.
Step-by-step instructions for the initial lighting of the pilot light.
Procedures for performing leak tests on the gas supply connections and pilot.
Lists the approved methods for testing gas leaks, emphasizing safety.
Detailed instructions on how to light the pilot flame using the built-in ignitor.
Steps for igniting the main burner after the pilot light is established.
Instructions on how to safely turn off the gas supply to the appliance.
Crucial safety warnings and procedures before lighting the electronic ignition system.
Step-by-step guide for lighting the fireplace using the electronic ignition system.
Procedures for safely shutting off the gas supply to the electronic ignition fireplace.
Steps for checking gas pressure specifically for the Signature Command system.
General guidelines and warnings for electrical wiring in the Signature Command system.
Wiring diagram illustrating connections for the Signature Command system components.
Instructions for mounting the Command Center wall unit.
Detailed steps for installing the optional fan/blower system.
Instructions and diagrams for wiring the optional fan/blower system.
Steps for connecting the AC box to the control box for the blower system.
Critical safety warnings specific to the Signature Command system before operation.
Step-by-step guide for operating the fireplace using the Signature Command system.
Instructions for safely turning off the gas supply for the Signature Command system.
Lists the features of the Command Center and Control Board for the Signature Command system.
Instructions for installing batteries in the Command Center unit.
Details system setup procedures like pilot type and safety shutdown options.
Instructions for pairing a remote transmitter with the system.
Procedure for turning off the standing pilot for maintenance or seasonal shutdown.
Explains how to use the Command Center for various functions like power, flame height, and turning off.
A chart for troubleshooting using the Command Center's diagnostic LED indications.
Step-by-step instructions for safely removing the glass frame from the fireplace.
Instructions on how to place rock wool to create glowing embers for the burner.
Detailed guide on correctly positioning the logs on the burner assembly.
Guidelines for placing lava rock and optional embers in the combustion chamber.
How to clean the internal components like logs and burner areas.
Guidance on visually checking the pilot flame during operation.
Instructions for visually checking the main burner flame appearance.
Recommendations for inspecting and maintaining the fireplace's vent system.
Procedures and precautions for cleaning the fireplace's glass door.
Instructions on how to clean the ceramic fiber logs.
Common causes and actions for troubleshooting pilot ignition problems.
Solutions for issues causing frequent pilot flame outages.
Troubleshooting steps when the pilot and main burner extinguish during operation.
Reasons and solutions for soot accumulation on the glass.
Addressing issues with blue flames or ghosting, often related to oxygen supply.
A flowchart for diagnosing and resolving issues with the Signature Command system.
An illustration showing the various components of the fireplace firebox.
A detailed list of firebox components and their corresponding part numbers for different models.
Lists part numbers for optional accessories and field-installed components.
An exploded view diagram of the standing pilot millivolt control system components.
Lists replacement parts for the standing pilot millivolt control system.
Part numbers for millivolt fuel conversion kits from natural gas to LP and vice versa.
An illustration showing the components of the electronic ignition system.
Lists replacement parts for the electronic ignition system for various models.
Part numbers for electronic ignition fuel conversion kits.
An illustration of the components for the Signature Command system.
Lists replacement parts for the Signature Command system, including accessories.
Part numbers for fuel conversion kits specific to the Signature Command system.
An illustration showing various vent components for the fireplace.
A list of vent components with part numbers from different manufacturers.
An illustration identifying the different log pieces for replacement.
Lists the part numbers for the fireplace logs for various models.
Special requirements for installing vented products in Massachusetts.
Mandates for carbon monoxide detectors and signage for installations in Massachusetts.
Details components covered under the lifetime warranty.
Details components covered under the five-year warranty.
Outlines the basic two-year warranty for materials and workmanship.
Instructions on how to obtain warranty service and what not to do.
A table showing the EnerGuide energy efficiency ratings for different fireplace models.
| Brand | Majestic |
|---|---|
| Model | 400DVB |
| Category | Indoor Fireplace |
| Language | English |












Loading...