OWNERS MANUAL FOR
2il )UHH Air Compressor
MODEL No
AC001
SPECIFICATION CHART
Model #AC00
HorsepRZHU+3
SCFM @ 40 PSIG 
SCFM @ 90 PSIG.
Cut-In Pressure PSI
Cut-Out Pressure 1 PSI
Bore mm
Stroke mm
Voltage -Single Phase 120
Motor RPM
Amperage @ max pressure 1.
Tank Size  Gallon
CSA/US Listed Yes
Minimum Circuit Requirement: 15 AMPS
*A circuit breaker is preferred. Use only a fuse or circuit
breaker that is the same rating as the branch circuit the air
compressor is operated on. If the air compressor is connected
to a circuit protected by fuses, use time delay fuses.
IMPORTANT — Read the Safety Guidelines and ALL
instructions carefully before operating.
www.makita.com

Questions and Answers:

Makita AC001 Specifications

General IconGeneral
BrandMakita
ModelAC001
CategoryAir Compressor
LanguageEnglish

Summary

Specification Chart

Important Safety Instructions

Risk of Unsafe Operation

Unsafe operation can lead to serious injury to you or others. Follow manual instructions and stay alert.

Risk of Air Tank Bursting

Improper handling of the tank can lead to explosion, causing serious injury. Drain tank daily and never modify.

Risk of Attachments and Accessories Bursting

Exceeding pressure ratings of tools can cause them to explode. Follow manufacturer recommendations.

Risk of Electric Shock

Improper electrical grounding or use can cause shock. Use qualified service personnel for repairs.

Risk of Explosion or Fire

Sparking during operation can ignite flammable vapors. Operate in well-ventilated areas away from fuels.

Risk to Breathing

Compressed air is not safe for breathing. It may contain carbon monoxide or spray material vapors.

Risk from Compressed Air

Compressed air can cause tissue damage and propel particles. Wear safety glasses and avoid pointing at others.

Risk from Moving Parts

Operating or repairing with power on exposes to moving parts. Always unplug before maintenance.

Risk of Burn

Contact with hot parts can cause severe burns. Allow unit to cool before touching.

Glossary

Duty Cycle

General Information

On-Receipt Inspection

Storage

Description of Operation

Installation and Break-in Procedures

Location of the Air Compressor

Locate compressor in a clean, dry, well-ventilated area, at least 12 inches from obstructions for cooling.

Initial Start Up Procedure

Open drain valve, plug in, run for 20 mins no-load to seat parts, then close drain valve.

Extension Cords

Use 3-wire grounded extension cords if necessary. Avoid voltage drop by using proper gauge and length.

Piping

Use only metal pipe for air distribution. Ensure correct size and bury underground lines below frost line.

Grounding Instruction

Proper grounding reduces shock risk. Use a grounded outlet conforming to codes. Do not use adapters.

Operating Procedures

Daily Start-up Checklist

Check switch, attach hose, build pressure via switch, adjust regulator. Ensure ventilation.

Maintenance

Routine Maintenance Schedule

Drain tank, check for noise/vibration, test safety valves, inspect fittings. Yearly checks on valves and pump.

Service Instructions

Units with External Brass Check Valve Replacement

Step-by-step guide to replace the check valve, including releasing pressure and removing components.

Motor

The motor has an automatic thermal overload protector. Allow to cool before resetting. Check for voltage issues.

Troubleshooting Guide

Makita Warranty